CopyPastehas never been so tasty!

HT1362c + Atmega8

byanonymous

    • 0
    • 0
    • 0
    21 views

    +00000000: C012 RJMP PC+0x0013 Relative jump
    +00000001: C02B RJMP PC+0x002C Relative jump
    +00000002: C02A RJMP PC+0x002B Relative jump
    +00000003: C029 RJMP PC+0x002A Relative jump
    +00000004: C1D7 RJMP PC+0x01D8 Relative jump
    +00000005: C027 RJMP PC+0x0028 Relative jump
    +00000006: C026 RJMP PC+0x0027 Relative jump
    +00000007: C025 RJMP PC+0x0026 Relative jump
    +00000008: C024 RJMP PC+0x0025 Relative jump
    +00000009: C023 RJMP PC+0x0024 Relative jump
    +0000000A: C022 RJMP PC+0x0023 Relative jump
    +0000000B: C021 RJMP PC+0x0022 Relative jump
    +0000000C: C020 RJMP PC+0x0021 Relative jump
    +0000000D: C01F RJMP PC+0x0020 Relative jump
    +0000000E: C01E RJMP PC+0x001F Relative jump
    +0000000F: C01D RJMP PC+0x001E Relative jump
    +00000010: C01C RJMP PC+0x001D Relative jump
    +00000011: C01B RJMP PC+0x001C Relative jump
    +00000012: C01A RJMP PC+0x001B Relative jump
    +00000013: 2411 CLR R1 Clear Register
    +00000014: BE1F OUT 0x3F,R1 Out to I/O location
    +00000015: E5CF LDI R28,0x5F Load immediate
    +00000016: E0D4 LDI R29,0x04 Load immediate
    +00000017: BFDE OUT 0x3E,R29 Out to I/O location
    +00000018: BFCD OUT 0x3D,R28 Out to I/O location
    +00000019: E011 LDI R17,0x01 Load immediate
    +0000001A: E6A0 LDI R26,0x60 Load immediate
    +0000001B: E0B0 LDI R27,0x00 Load immediate
    +0000001C: E8E8 LDI R30,0x88 Load immediate
    +0000001D: E0FC LDI R31,0x0C Load immediate
    +0000001E: C002 RJMP PC+0x0003 Relative jump
    +0000001F: 9005 LPM R0,Z+ Load program memory and postincrement
    +00000020: 920D ST X+,R0 Store indirect and postincrement
    +00000021: 31AC CPI R26,0x1C Compare with immediate
    +00000022: 07B1 CPC R27,R17 Compare with carry
    +00000023: F7D9 BRNE PC-0x04 Branch if not equal
    +00000024: E011 LDI R17,0x01 Load immediate
    +00000025: E1AC LDI R26,0x1C Load immediate
    +00000026: E0B1 LDI R27,0x01 Load immediate
    +00000027: C001 RJMP PC+0x0002 Relative jump
    +00000028: 921D ST X+,R1 Store indirect and postincrement
    +00000029: 3AA4 CPI R26,0xA4 Compare with immediate
    +0000002A: 07B1 CPC R27,R17 Compare with carry
    +0000002B: F7E1 BRNE PC-0x03 Branch if not equal
    +0000002C: C5C1 RJMP PC+0x05C2 Relative jump
    +0000002D: CFD2 RJMP PC-0x002D Relative jump
    +0000002E: 2F98 MOV R25,R24 Copy register
    +0000002F: 3041 CPI R20,0x01 Compare with immediate
    +00000030: F479 BRNE PC+0x10 Branch if not equal
    +00000031: E080 LDI R24,0x00 Load immediate
    +00000032: 1786 CP R24,R22 Compare
    +00000033: F4C8 BRCC PC+0x1A Branch if carry cleared
    +00000034: 98C4 CBI 0x18,4 Clear bit in I/O register
    +00000035: FF97 SBRS R25,7 Skip if bit in register set
    +00000036: C002 RJMP PC+0x0003 Relative jump
    +00000037: 9AC5 SBI 0x18,5 Set bit in I/O register
    +00000038: C001 RJMP PC+0x0002 Relative jump
    +00000039: 98C5 CBI 0x18,5 Clear bit in I/O register
    +0000003A: 0F99 LSL R25 Logical Shift Left
    +0000003B: 9AC4 SBI 0x18,4 Set bit in I/O register
    +0000003C: 5F8F SUBI R24,0xFF Subtract immediate
    +0000003D: 1786 CP R24,R22 Compare
    +0000003E: F3A8 BRCS PC-0x0A Branch if carry set
    +0000003F: 9508 RET Subroutine return
    +00000040: E080 LDI R24,0x00 Load immediate
    +00000041: 1786 CP R24,R22 Compare
    +00000042: F450 BRCC PC+0x0B Branch if carry cleared
    +00000043: 98C4 CBI 0x18,4 Clear bit in I/O register
    +00000044: FF90 SBRS R25,0 Skip if bit in register set
    +00000045: C002 RJMP PC+0x0003 Relative jump
    +00000046: 9AC5 SBI 0x18,5 Set bit in I/O register
    +00000047: C001 RJMP PC+0x0002 Relative jump
    +00000048: 98C5 CBI 0x18,5 Clear bit in I/O register
    +00000049: 9596 LSR R25 Logical shift right
    +0000004A: 9AC4 SBI 0x18,4 Set bit in I/O register
    +0000004B: 5F8F SUBI R24,0xFF Subtract immediate
    +0000004C: CFF4 RJMP PC-0x000B Relative jump
    +0000004D: 9508 RET Subroutine return
    +0000004E: 931F PUSH R17 Push register on stack
    +0000004F: 2F18 MOV R17,R24 Copy register
    +00000050: 98C3 CBI 0x18,3 Clear bit in I/O register
    +00000051: E041 LDI R20,0x01 Load immediate
    +00000052: E063 LDI R22,0x03 Load immediate
    +00000053: E880 LDI R24,0x80 Load immediate
    +00000054: DFD9 RCALL PC-0x0026 Relative call subroutine
    +00000055: E041 LDI R20,0x01 Load immediate
    +00000056: E069 LDI R22,0x09 Load immediate
    +00000057: 2F81 MOV R24,R17 Copy register
    +00000058: DFD5 RCALL PC-0x002A Relative call subroutine
    +00000059: 9AC3 SBI 0x18,3 Set bit in I/O register
    +0000005A: 911F POP R17 Pop register from stack
    +0000005B: 9508 RET Subroutine return
    +0000005C: 930F PUSH R16 Push register on stack
    +0000005D: 931F PUSH R17 Push register on stack
    +0000005E: 2F18 MOV R17,R24 Copy register
    +0000005F: 2F06 MOV R16,R22 Copy register
    +00000060: 98C3 CBI 0x18,3 Clear bit in I/O register
    +00000061: E041 LDI R20,0x01 Load immediate
    +00000062: E063 LDI R22,0x03 Load immediate
    +00000063: EA80 LDI R24,0xA0 Load immediate
    +00000064: DFC9 RCALL PC-0x0036 Relative call subroutine
    +00000065: E041 LDI R20,0x01 Load immediate
    +00000066: E067 LDI R22,0x07 Load immediate
    +00000067: 2F81 MOV R24,R17 Copy register
    +00000068: 2E04 MOV R0,R20 Copy register
    +00000069: C001 RJMP PC+0x0002 Relative jump
    +0000006A: 0F88 LSL R24 Logical Shift Left
    +0000006B: 940A DEC R0 Decrement
    +0000006C: F7EA BRPL PC-0x02 Branch if plus
    +0000006D: DFC0 RCALL PC-0x003F Relative call subroutine
    +0000006E: E040 LDI R20,0x00 Load immediate
    +0000006F: E068 LDI R22,0x08 Load immediate
    +00000070: 2F80 MOV R24,R16 Copy register
    +00000071: DFBC RCALL PC-0x0043 Relative call subroutine
    +00000072: 9AC3 SBI 0x18,3 Set bit in I/O register
    +00000073: 911F POP R17 Pop register from stack
    +00000074: 910F POP R16 Pop register from stack
    +00000075: 9508 RET Subroutine return
    +00000076: 930F PUSH R16 Push register on stack
    +00000077: 931F PUSH R17 Push register on stack
    +00000078: 93CF PUSH R28 Push register on stack
    +00000079: 93DF PUSH R29 Push register on stack
    +0000007A: 2F18 MOV R17,R24 Copy register
    +0000007B: 01EB MOVW R28,R22 Copy register pair
    +0000007C: 2F04 MOV R16,R20 Copy register
    +0000007D: 98C3 CBI 0x18,3 Clear bit in I/O register
    +0000007E: E041 LDI R20,0x01 Load immediate
    +0000007F: E063 LDI R22,0x03 Load immediate
    +00000080: EA80 LDI R24,0xA0 Load immediate
    +00000081: DFAC RCALL PC-0x0053 Relative call subroutine
    +00000082: E041 LDI R20,0x01 Load immediate
    +00000083: E067 LDI R22,0x07 Load immediate
    +00000084: 2F81 MOV R24,R17 Copy register
    +00000085: 2E04 MOV R0,R20 Copy register
    +00000086: C001 RJMP PC+0x0002 Relative jump
    +00000087: 0F88 LSL R24 Logical Shift Left
    +00000088: 940A DEC R0 Decrement
    +00000089: F7EA BRPL PC-0x02 Branch if plus
    +0000008A: DFA3 RCALL PC-0x005C Relative call subroutine
    +0000008B: E010 LDI R17,0x00 Load immediate
    +0000008C: 1710 CP R17,R16 Compare
    +0000008D: F430 BRCC PC+0x07 Branch if carry cleared
    +0000008E: E040 LDI R20,0x00 Load immediate
    +0000008F: E068 LDI R22,0x08 Load immediate
    +00000090: 9189 LD R24,Y+ Load indirect and postincrement
    +00000091: DF9C RCALL PC-0x0063 Relative call subroutine
    +00000092: 5F1F SUBI R17,0xFF Subtract immediate
    +00000093: CFF8 RJMP PC-0x0007 Relative jump
    +00000094: 9AC3 SBI 0x18,3 Set bit in I/O register
    +00000095: 91DF POP R29 Pop register from stack
    +00000096: 91CF POP R28 Pop register from stack
    +00000097: 911F POP R17 Pop register from stack
    +00000098: 910F POP R16 Pop register from stack
    +00000099: 9508 RET Subroutine return
    +0000009A: 93CF PUSH R28 Push register on stack
    +0000009B: 98C3 CBI 0x18,3 Clear bit in I/O register
    +0000009C: E041 LDI R20,0x01 Load immediate
    +0000009D: E063 LDI R22,0x03 Load immediate
    +0000009E: EA80 LDI R24,0xA0 Load immediate
    +0000009F: DF8E RCALL PC-0x0071 Relative call subroutine
    +000000A0: E041 LDI R20,0x01 Load immediate
    +000000A1: E067 LDI R22,0x07 Load immediate
    +000000A2: E080 LDI R24,0x00 Load immediate
    +000000A3: DF8A RCALL PC-0x0075 Relative call subroutine
    +000000A4: E1CF LDI R28,0x1F Load immediate
    +000000A5: E040 LDI R20,0x00 Load immediate
    +000000A6: E068 LDI R22,0x08 Load immediate
    +000000A7: 2F84 MOV R24,R20 Copy register
    +000000A8: DF85 RCALL PC-0x007A Relative call subroutine
    +000000A9: 50C1 SUBI R28,0x01 Subtract immediate
    +000000AA: FFC7 SBRS R28,7 Skip if bit in register set
    +000000AB: CFF9 RJMP PC-0x0006 Relative jump
    +000000AC: 9AC3 SBI 0x18,3 Set bit in I/O register
    +000000AD: 91CF POP R28 Pop register from stack
    +000000AE: 9508 RET Subroutine return
    +000000AF: 9AC3 SBI 0x18,3 Set bit in I/O register
    +000000B0: 9AC4 SBI 0x18,4 Set bit in I/O register
    +000000B1: 9AC5 SBI 0x18,5 Set bit in I/O register
    +000000B2: E080 LDI R24,0x00 Load immediate
    +000000B3: DF9A RCALL PC-0x0065 Relative call subroutine
    +000000B4: E280 LDI R24,0x20 Load immediate
    +000000B5: DF98 RCALL PC-0x0067 Relative call subroutine
    +000000B6: E188 LDI R24,0x18 Load immediate
    +000000B7: DF96 RCALL PC-0x0069 Relative call subroutine
    +000000B8: E081 LDI R24,0x01 Load immediate
    +000000B9: DF94 RCALL PC-0x006B Relative call subroutine
    +000000BA: EA80 LDI R24,0xA0 Load immediate
    +000000BB: DF92 RCALL PC-0x006D Relative call subroutine
    +000000BC: E088 LDI R24,0x08 Load immediate
    +000000BD: DF90 RCALL PC-0x006F Relative call subroutine
    +000000BE: E083 LDI R24,0x03 Load immediate
    +000000BF: DF8E RCALL PC-0x0071 Relative call subroutine
    +000000C0: DFD9 RCALL PC-0x0026 Relative call subroutine
    +000000C1: 9508 RET Subroutine return
    +000000C2: 9AA2 SBI 0x14,2 Set bit in I/O register
    +000000C3: 98AA CBI 0x15,2 Clear bit in I/O register
    +000000C4: EB87 LDI R24,0xB7 Load immediate
    +000000C5: 958A DEC R24 Decrement
    +000000C6: F7F1 BRNE PC-0x01 Branch if not equal
    +000000C7: 98A2 CBI 0x14,2 Clear bit in I/O register
    +000000C8: 9AAA SBI 0x15,2 Set bit in I/O register
    +000000C9: E184 LDI R24,0x14 Load immediate
    +000000CA: 958A DEC R24 Decrement
    +000000CB: F7F1 BRNE PC-0x01 Branch if not equal
    +000000CC: B393 IN R25,0x13 In from I/O location
    +000000CD: 7094 ANDI R25,0x04 Logical AND with immediate
    +000000CE: E580 LDI R24,0x50 Load immediate
    +000000CF: 958A DEC R24 Decrement
    +000000D0: F7F1 BRNE PC-0x01 Branch if not equal
    +000000D1: 2F89 MOV R24,R25 Copy register
    +000000D2: 2799 CLR R25 Clear Register
    +000000D3: 9508 RET Subroutine return
    +000000D4: 2F98 MOV R25,R24 Copy register
    +000000D5: E124 LDI R18,0x14 Load immediate
    +000000D6: E030 LDI R19,0x00 Load immediate
    +000000D7: E040 LDI R20,0x00 Load immediate
    +000000D8: E050 LDI R21,0x00 Load immediate
    +000000D9: E067 LDI R22,0x07 Load immediate
    +000000DA: 9AA2 SBI 0x14,2 Set bit in I/O register
    +000000DB: 98AA CBI 0x15,2 Clear bit in I/O register
    +000000DC: FD90 SBRC R25,0 Skip if bit in register cleared
    +000000DD: 9AAA SBI 0x15,2 Set bit in I/O register
    +000000DE: 2F82 MOV R24,R18 Copy register
    +000000DF: 958A DEC R24 Decrement
    +000000E0: F7F1 BRNE PC-0x01 Branch if not equal
    +000000E1: 9AAA SBI 0x15,2 Set bit in I/O register
    +000000E2: 9596 LSR R25 Logical shift right
    +000000E3: 5061 SUBI R22,0x01 Subtract immediate
    +000000E4: FF67 SBRS R22,7 Skip if bit in register set
    +000000E5: CFF4 RJMP PC-0x000B Relative jump
    +000000E6: 9508 RET Subroutine return
    +000000E7: E090 LDI R25,0x00 Load immediate
    +000000E8: E124 LDI R18,0x14 Load immediate
    +000000E9: E030 LDI R19,0x00 Load immediate
    +000000EA: E040 LDI R20,0x00 Load immediate
    +000000EB: E050 LDI R21,0x00 Load immediate
    +000000EC: E067 LDI R22,0x07 Load immediate
    +000000ED: 9596 LSR R25 Logical shift right
    +000000EE: 9AA2 SBI 0x14,2 Set bit in I/O register
    +000000EF: 98AA CBI 0x15,2 Clear bit in I/O register
    +000000F0: 98A2 CBI 0x14,2 Clear bit in I/O register
    +000000F1: 9AAA SBI 0x15,2 Set bit in I/O register
    +000000F2: 999A SBIC 0x13,2 Skip if bit in I/O register cleared
    +000000F3: 6890 ORI R25,0x80 Logical OR with immediate
    +000000F4: 2F82 MOV R24,R18 Copy register
    +000000F5: 958A DEC R24 Decrement
    +000000F6: F7F1 BRNE PC-0x01 Branch if not equal
    +000000F7: 5061 SUBI R22,0x01 Subtract immediate
    +000000F8: FF67 SBRS R22,7 Skip if bit in register set
    +000000F9: CFF3 RJMP PC-0x000C Relative jump
    +000000FA: 2F89 MOV R24,R25 Copy register
    +000000FB: 2799 CLR R25 Clear Register
    +000000FC: 9508 RET Subroutine return
    +000000FD: 931F PUSH R17 Push register on stack
    +000000FE: 2F18 MOV R17,R24 Copy register
    +000000FF: DFC2 RCALL PC-0x003D Relative call subroutine
    +00000100: EC8C LDI R24,0xCC Load immediate
    +00000101: DFD2 RCALL PC-0x002D Relative call subroutine
    +00000102: E48E LDI R24,0x4E Load immediate
    +00000103: DFD0 RCALL PC-0x002F Relative call subroutine
    +00000104: E082 LDI R24,0x02 Load immediate
    +00000105: DFCE RCALL PC-0x0031 Relative call subroutine
    +00000106: E081 LDI R24,0x01 Load immediate
    +00000107: DFCC RCALL PC-0x0033 Relative call subroutine
    +00000108: 2F81 MOV R24,R17 Copy register
    +00000109: DFCA RCALL PC-0x0035 Relative call subroutine
    +0000010A: DFB7 RCALL PC-0x0048 Relative call subroutine
    +0000010B: EC8C LDI R24,0xCC Load immediate
    +0000010C: DFC7 RCALL PC-0x0038 Relative call subroutine
    +0000010D: E488 LDI R24,0x48 Load immediate
    +0000010E: DFC5 RCALL PC-0x003A Relative call subroutine
    +0000010F: 911F POP R17 Pop register from stack
    +00000110: 9508 RET Subroutine return
    +00000111: B387 IN R24,0x17 In from I/O location
    +00000112: 6388 ORI R24,0x38 Logical OR with immediate
    +00000113: BB87 OUT 0x17,R24 Out to I/O location
    +00000114: B388 IN R24,0x18 In from I/O location
    +00000115: 6388 ORI R24,0x38 Logical OR with immediate
    +00000116: BB88 OUT 0x18,R24 Out to I/O location
    +00000117: B381 IN R24,0x11 In from I/O location
    +00000118: 718F ANDI R24,0x1F Logical AND with immediate
    +00000119: BB81 OUT 0x11,R24 Out to I/O location
    +0000011A: B382 IN R24,0x12 In from I/O location
    +0000011B: 6E80 ORI R24,0xE0 Logical OR with immediate
    +0000011C: BB82 OUT 0x12,R24 Out to I/O location
    +0000011D: 9508 RET Subroutine return
    +0000011E: 9180019B LDS R24,0x019B Load direct from data space
    +00000120: 3082 CPI R24,0x02 Compare with immediate
    +00000121: F441 BRNE PC+0x09 Branch if not equal
    +00000122: 918001A2 LDS R24,0x01A2 Load direct from data space
    +00000124: 7083 ANDI R24,0x03 Logical AND with immediate
    +00000125: F411 BRNE PC+0x03 Branch if not equal
    +00000126: E18D LDI R24,0x1D Load immediate
    +00000127: C00A RJMP PC+0x000B Relative jump
    +00000128: E18C LDI R24,0x1C Load immediate
    +00000129: C008 RJMP PC+0x0009 Relative jump
    +0000012A: 3088 CPI R24,0x08 Compare with immediate
    +0000012B: F00C BRLT PC+0x02 Branch if less than, signed
    +0000012C: 5087 SUBI R24,0x07 Subtract immediate
    +0000012D: FF80 SBRS R24,0 Skip if bit in register set
    +0000012E: C002 RJMP PC+0x0003 Relative jump
    +0000012F: E18F LDI R24,0x1F Load immediate
    +00000130: C001 RJMP PC+0x0002 Relative jump
    +00000131: E18E LDI R24,0x1E Load immediate
    +00000132: 2799 CLR R25 Clear Register
    +00000133: 9508 RET Subroutine return
    +00000134: 930F PUSH R16 Push register on stack
    +00000135: 931F PUSH R17 Push register on stack
    +00000136: 93CF PUSH R28 Push register on stack
    +00000137: 93DF PUSH R29 Push register on stack
    +00000138: 91500060 LDS R21,0x0060 Load direct from data space
    +0000013A: E1AF LDI R26,0x1F Load immediate
    +0000013B: E0B1 LDI R27,0x01 Load immediate
    +0000013C: E020 LDI R18,0x00 Load immediate
    +0000013D: E030 LDI R19,0x00 Load immediate
    +0000013E: E047 LDI R20,0x07 Load immediate
    +0000013F: 2F85 MOV R24,R21 Copy register
    +00000140: E06A LDI R22,0x0A Load immediate
    +00000141: D4E9 RCALL PC+0x04EA Relative call subroutine
    +00000142: 2FE8 MOV R30,R24 Copy register
    +00000143: 27FF CLR R31 Clear Register
    +00000144: FDE7 SBRC R30,7 Skip if bit in register cleared
    +00000145: 95F0 COM R31 One's complement
    +00000146: E063 LDI R22,0x03 Load immediate
    +00000147: 0FEE LSL R30 Logical Shift Left
    +00000148: 1FFF ROL R31 Rotate Left Through Carry
    +00000149: 956A DEC R22 Decrement
    +0000014A: F7E1 BRNE PC-0x03 Branch if not equal
    +0000014B: 0FE2 ADD R30,R18 Add without carry
    +0000014C: 1FF3 ADC R31,R19 Add with carry
    +0000014D: 58E4 SUBI R30,0x84 Subtract immediate
    +0000014E: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +0000014F: 8180 LDD R24,Z+0 Load indirect with displacement
    +00000150: 938D ST X+,R24 Store indirect and postincrement
    +00000151: 5041 SUBI R20,0x01 Subtract immediate
    +00000152: 5F2F SUBI R18,0xFF Subtract immediate
    +00000153: 4F3F SBCI R19,0xFF Subtract immediate with carry
    +00000154: FF47 SBRS R20,7 Skip if bit in register set
    +00000155: CFE9 RJMP PC-0x0016 Relative jump
    +00000156: E040 LDI R20,0x00 Load immediate
    +00000157: E606 LDI R16,0x66 Load immediate
    +00000158: E010 LDI R17,0x00 Load immediate
    +00000159: E2C7 LDI R28,0x27 Load immediate
    +0000015A: E0D1 LDI R29,0x01 Load immediate
    +0000015B: E0A0 LDI R26,0x00 Load immediate
    +0000015C: E0B0 LDI R27,0x00 Load immediate
    +0000015D: 2F85 MOV R24,R21 Copy register
    +0000015E: E06A LDI R22,0x0A Load immediate
    +0000015F: D4CB RCALL PC+0x04CC Relative call subroutine
    +00000160: 2FE9 MOV R30,R25 Copy register
    +00000161: 27FF CLR R31 Clear Register
    +00000162: FDE7 SBRC R30,7 Skip if bit in register cleared
    +00000163: 95F0 COM R31 One's complement
    +00000164: E033 LDI R19,0x03 Load immediate
    +00000165: 0FEE LSL R30 Logical Shift Left
    +00000166: 1FFF ROL R31 Rotate Left Through Carry
    +00000167: 953A DEC R19 Decrement
    +00000168: F7E1 BRNE PC-0x03 Branch if not equal
    +00000169: 0FEA ADD R30,R26 Add without carry
    +0000016A: 1FFB ADC R31,R27 Add with carry
    +0000016B: 58E4 SUBI R30,0x84 Subtract immediate
    +0000016C: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +0000016D: 8120 LDD R18,Z+0 Load indirect with displacement
    +0000016E: 9526 LSR R18 Logical shift right
    +0000016F: 2F84 MOV R24,R20 Copy register
    +00000170: 7087 ANDI R24,0x07 Logical AND with immediate
    +00000171: 01B8 MOVW R22,R16 Copy register pair
    +00000172: C002 RJMP PC+0x0003 Relative jump
    +00000173: 0F66 LSL R22 Logical Shift Left
    +00000174: 1F77 ROL R23 Rotate Left Through Carry
    +00000175: 958A DEC R24 Decrement
    +00000176: F7E2 BRPL PC-0x03 Branch if plus
    +00000177: 01CB MOVW R24,R22 Copy register pair
    +00000178: 7880 ANDI R24,0x80 Logical AND with immediate
    +00000179: 2B28 OR R18,R24 Logical OR
    +0000017A: 9329 ST Y+,R18 Store indirect and postincrement
    +0000017B: 5F4F SUBI R20,0xFF Subtract immediate
    +0000017C: 9611 ADIW R26,0x01 Add immediate to word
    +0000017D: 3048 CPI R20,0x08 Compare with immediate
    +0000017E: F2F0 BRCS PC-0x21 Branch if carry set
    +0000017F: E040 LDI R20,0x00 Load immediate
    +00000180: 9150019D LDS R21,0x019D Load direct from data space
    +00000182: E606 LDI R16,0x66 Load immediate
    +00000183: E010 LDI R17,0x00 Load immediate
    +00000184: E2CF LDI R28,0x2F Load immediate
    +00000185: E0D1 LDI R29,0x01 Load immediate
    +00000186: E0A0 LDI R26,0x00 Load immediate
    +00000187: E0B0 LDI R27,0x00 Load immediate
    +00000188: 2F85 MOV R24,R21 Copy register
    +00000189: E06A LDI R22,0x0A Load immediate
    +0000018A: D4A0 RCALL PC+0x04A1 Relative call subroutine
    +0000018B: 2FE8 MOV R30,R24 Copy register
    +0000018C: 27FF CLR R31 Clear Register
    +0000018D: FDE7 SBRC R30,7 Skip if bit in register cleared
    +0000018E: 95F0 COM R31 One's complement
    +0000018F: E023 LDI R18,0x03 Load immediate
    +00000190: 0FEE LSL R30 Logical Shift Left
    +00000191: 1FFF ROL R31 Rotate Left Through Carry
    +00000192: 952A DEC R18 Decrement
    +00000193: F7E1 BRNE PC-0x03 Branch if not equal
    +00000194: 0FEA ADD R30,R26 Add without carry
    +00000195: 1FFB ADC R31,R27 Add with carry
    +00000196: 58E4 SUBI R30,0x84 Subtract immediate
    +00000197: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +00000198: 8180 LDD R24,Z+0 Load indirect with displacement
    +00000199: 2F28 MOV R18,R24 Copy register
    +0000019A: 2733 CLR R19 Clear Register
    +0000019B: 0F22 LSL R18 Logical Shift Left
    +0000019C: 1F33 ROL R19 Rotate Left Through Carry
    +0000019D: 2F84 MOV R24,R20 Copy register
    +0000019E: 7087 ANDI R24,0x07 Logical AND with immediate
    +0000019F: 01B8 MOVW R22,R16 Copy register pair
    +000001A0: C002 RJMP PC+0x0003 Relative jump
    +000001A1: 9575 ASR R23 Arithmetic shift right
    +000001A2: 9567 ROR R22 Rotate right through carry
    +000001A3: 958A DEC R24 Decrement
    +000001A4: F7E2 BRPL PC-0x03 Branch if plus
    +000001A5: 01CB MOVW R24,R22 Copy register pair
    +000001A6: 7081 ANDI R24,0x01 Logical AND with immediate
    +000001A7: 2B82 OR R24,R18 Logical OR
    +000001A8: 9389 ST Y+,R24 Store indirect and postincrement
    +000001A9: 5F4F SUBI R20,0xFF Subtract immediate
    +000001AA: 9611 ADIW R26,0x01 Add immediate to word
    +000001AB: 3048 CPI R20,0x08 Compare with immediate
    +000001AC: F2D8 BRCS PC-0x24 Branch if carry set
    +000001AD: E3A7 LDI R26,0x37 Load immediate
    +000001AE: E0B1 LDI R27,0x01 Load immediate
    +000001AF: E020 LDI R18,0x00 Load immediate
    +000001B0: E030 LDI R19,0x00 Load immediate
    +000001B1: E047 LDI R20,0x07 Load immediate
    +000001B2: 2F85 MOV R24,R21 Copy register
    +000001B3: E06A LDI R22,0x0A Load immediate
    +000001B4: D476 RCALL PC+0x0477 Relative call subroutine
    +000001B5: 2FE9 MOV R30,R25 Copy register
    +000001B6: 27FF CLR R31 Clear Register
    +000001B7: FDE7 SBRC R30,7 Skip if bit in register cleared
    +000001B8: 95F0 COM R31 One's complement
    +000001B9: E083 LDI R24,0x03 Load immediate
    +000001BA: 0FEE LSL R30 Logical Shift Left
    +000001BB: 1FFF ROL R31 Rotate Left Through Carry
    +000001BC: 958A DEC R24 Decrement
    +000001BD: F7E1 BRNE PC-0x03 Branch if not equal
    +000001BE: 0FE2 ADD R30,R18 Add without carry
    +000001BF: 1FF3 ADC R31,R19 Add with carry
    +000001C0: 58E4 SUBI R30,0x84 Subtract immediate
    +000001C1: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +000001C2: 8180 LDD R24,Z+0 Load indirect with displacement
    +000001C3: 938D ST X+,R24 Store indirect and postincrement
    +000001C4: 5041 SUBI R20,0x01 Subtract immediate
    +000001C5: 5F2F SUBI R18,0xFF Subtract immediate
    +000001C6: 4F3F SBCI R19,0xFF Subtract immediate with carry
    +000001C7: FF47 SBRS R20,7 Skip if bit in register set
    +000001C8: CFE9 RJMP PC-0x0016 Relative jump
    +000001C9: 91DF POP R29 Pop register from stack
    +000001CA: 91CF POP R28 Pop register from stack
    +000001CB: 911F POP R17 Pop register from stack
    +000001CC: 910F POP R16 Pop register from stack
    +000001CD: 9508 RET Subroutine return
    +000001CE: BC15 OUT 0x25,R1 Out to I/O location
    +000001CF: E088 LDI R24,0x08 Load immediate
    +000001D0: BD82 OUT 0x22,R24 Out to I/O location
    +000001D1: EF88 LDI R24,0xF8 Load immediate
    +000001D2: BD84 OUT 0x24,R24 Out to I/O location
    +000001D3: E087 LDI R24,0x07 Load immediate
    +000001D4: BD85 OUT 0x25,R24 Out to I/O location
    +000001D5: B78F IN R24,0x3F In from I/O location
    +000001D6: 6880 ORI R24,0x80 Logical OR with immediate
    +000001D7: BF8F OUT 0x3F,R24 Out to I/O location
    +000001D8: B789 IN R24,0x39 In from I/O location
    +000001D9: 6480 ORI R24,0x40 Logical OR with immediate
    +000001DA: BF89 OUT 0x39,R24 Out to I/O location
    +000001DB: 9508 RET Subroutine return
    +000001DC: 921F PUSH R1 Push register on stack
    +000001DD: 920F PUSH R0 Push register on stack
    +000001DE: B60F IN R0,0x3F In from I/O location
    +000001DF: 920F PUSH R0 Push register on stack
    +000001E0: 2411 CLR R1 Clear Register
    +000001E1: 931F PUSH R17 Push register on stack
    +000001E2: 932F PUSH R18 Push register on stack
    +000001E3: 933F PUSH R19 Push register on stack
    +000001E4: 934F PUSH R20 Push register on stack
    +000001E5: 935F PUSH R21 Push register on stack
    +000001E6: 936F PUSH R22 Push register on stack
    +000001E7: 937F PUSH R23 Push register on stack
    +000001E8: 938F PUSH R24 Push register on stack
    +000001E9: 939F PUSH R25 Push register on stack
    +000001EA: 93AF PUSH R26 Push register on stack
    +000001EB: 93BF PUSH R27 Push register on stack
    +000001EC: 93EF PUSH R30 Push register on stack
    +000001ED: 93FF PUSH R31 Push register on stack
    +000001EE: EF88 LDI R24,0xF8 Load immediate
    +000001EF: BD84 OUT 0x24,R24 Out to I/O location
    +000001F0: 9180019A LDS R24,0x019A Load direct from data space
    +000001F2: 5F8F SUBI R24,0xFF Subtract immediate
    +000001F3: 9380019A STS 0x019A,R24 Store direct to data space
    +000001F5: 3289 CPI R24,0x29 Compare with immediate
    +000001F6: F020 BRCS PC+0x05 Branch if carry set
    +000001F7: 9210019A STS 0x019A,R1 Store direct to data space
    +000001F9: 92100198 STS 0x0198,R1 Store direct to data space
    +000001FB: 9180011E LDS R24,0x011E Load direct from data space
    +000001FD: 5F8F SUBI R24,0xFF Subtract immediate
    +000001FE: 9380011E STS 0x011E,R24 Store direct to data space
    +00000200: 3082 CPI R24,0x02 Compare with immediate
    +00000201: F038 BRCS PC+0x08 Branch if carry set
    +00000202: 9180011D LDS R24,0x011D Load direct from data space
    +00000204: 5F8F SUBI R24,0xFF Subtract immediate
    +00000205: 9380011D STS 0x011D,R24 Store direct to data space
    +00000207: 9210011E STS 0x011E,R1 Store direct to data space
    +00000209: 9180011D LDS R24,0x011D Load direct from data space
    +0000020B: 3082 CPI R24,0x02 Compare with immediate
    +0000020C: F408 BRCC PC+0x02 Branch if carry cleared
    +0000020D: C07E RJMP PC+0x007F Relative jump
    +0000020E: 9210011D STS 0x011D,R1 Store direct to data space
    +00000210: 9120019C LDS R18,0x019C Load direct from data space
    +00000212: 5F2F SUBI R18,0xFF Subtract immediate
    +00000213: 9320019C STS 0x019C,R18 Store direct to data space
    +00000215: 9130019D LDS R19,0x019D Load direct from data space
    +00000217: 2F83 MOV R24,R19 Copy register
    +00000218: E065 LDI R22,0x05 Load immediate
    +00000219: D411 RCALL PC+0x0412 Relative call subroutine
    +0000021A: 2399 TST R25 Test for Zero or Minus
    +0000021B: F479 BRNE PC+0x10 Branch if not equal
    +0000021C: 302A CPI R18,0x0A Compare with immediate
    +0000021D: F469 BRNE PC+0x0E Branch if not equal
    +0000021E: 91800198 LDS R24,0x0198 Load direct from data space
    +00000220: 2388 TST R24 Test for Zero or Minus
    +00000221: F449 BRNE PC+0x0A Branch if not equal
    +00000222: 91900199 LDS R25,0x0199 Load direct from data space
    +00000224: 2399 TST R25 Test for Zero or Minus
    +00000225: F429 BRNE PC+0x06 Branch if not equal
    +00000226: E081 LDI R24,0x01 Load immediate
    +00000227: 93800199 STS 0x0199,R24 Store direct to data space
    +00000229: 93900197 STS 0x0197,R25 Store direct to data space
    +0000022B: 9180019C LDS R24,0x019C Load direct from data space
    +0000022D: 338C CPI R24,0x3C Compare with immediate
    +0000022E: F40C BRGE PC+0x02 Branch if greater or equal, signed
    +0000022F: C05C RJMP PC+0x005D Relative jump
    +00000230: 2F83 MOV R24,R19 Copy register
    +00000231: 5F8F SUBI R24,0xFF Subtract immediate
    +00000232: 9380019D STS 0x019D,R24 Store direct to data space
    +00000234: 9210019C STS 0x019C,R1 Store direct to data space
    +00000236: 338C CPI R24,0x3C Compare with immediate
    +00000237: F40C BRGE PC+0x02 Branch if greater or equal, signed
    +00000238: C053 RJMP PC+0x0054 Relative jump
    +00000239: 91800060 LDS R24,0x0060 Load direct from data space
    +0000023B: 5F8F SUBI R24,0xFF Subtract immediate
    +0000023C: 93800060 STS 0x0060,R24 Store direct to data space
    +0000023E: 9210019D STS 0x019D,R1 Store direct to data space
    +00000240: 3188 CPI R24,0x18 Compare with immediate
    +00000241: F40C BRGE PC+0x02 Branch if greater or equal, signed
    +00000242: C049 RJMP PC+0x004A Relative jump
    +00000243: 911001A3 LDS R17,0x01A3 Load direct from data space
    +00000245: 5F1F SUBI R17,0xFF Subtract immediate
    +00000246: 931001A3 STS 0x01A3,R17 Store direct to data space
    +00000248: 92100060 STS 0x0060,R1 Store direct to data space
    +0000024A: DED3 RCALL PC-0x012C Relative call subroutine
    +0000024B: 2F21 MOV R18,R17 Copy register
    +0000024C: 2733 CLR R19 Clear Register
    +0000024D: FD27 SBRC R18,7 Skip if bit in register cleared
    +0000024E: 9530 COM R19 One's complement
    +0000024F: 2799 CLR R25 Clear Register
    +00000250: 1782 CP R24,R18 Compare
    +00000251: 0793 CPC R25,R19 Compare with carry
    +00000252: F4AC BRGE PC+0x16 Branch if greater or equal, signed
    +00000253: 9180019B LDS R24,0x019B Load direct from data space
    +00000255: 5F8F SUBI R24,0xFF Subtract immediate
    +00000256: 9380019B STS 0x019B,R24 Store direct to data space
    +00000258: E091 LDI R25,0x01 Load immediate
    +00000259: 939001A3 STS 0x01A3,R25 Store direct to data space
    +0000025B: 308D CPI R24,0x0D Compare with immediate
    +0000025C: F05C BRLT PC+0x0C Branch if less than, signed
    +0000025D: 918001A2 LDS R24,0x01A2 Load direct from data space
    +0000025F: 0F89 ADD R24,R25 Add without carry
    +00000260: 938001A2 STS 0x01A2,R24 Store direct to data space
    +00000262: 9390019B STS 0x019B,R25 Store direct to data space
    +00000264: 3684 CPI R24,0x64 Compare with immediate
    +00000265: F014 BRLT PC+0x03 Branch if less than, signed
    +00000266: 921001A2 STS 0x01A2,R1 Store direct to data space
    +00000268: 912001A3 LDS R18,0x01A3 Load direct from data space
    +0000026A: 2F82 MOV R24,R18 Copy register
    +0000026B: E06A LDI R22,0x0A Load immediate
    +0000026C: D3BE RCALL PC+0x03BF Relative call subroutine
    +0000026D: 93800069 STS 0x0069,R24 Store direct to data space
    +0000026F: 2F82 MOV R24,R18 Copy register
    +00000270: E06A LDI R22,0x0A Load immediate
    +00000271: D3B9 RCALL PC+0x03BA Relative call subroutine
    +00000272: 9390006A STS 0x006A,R25 Store direct to data space
    +00000274: 9120019B LDS R18,0x019B Load direct from data space
    +00000276: 2F82 MOV R24,R18 Copy register
    +00000277: E06A LDI R22,0x0A Load immediate
    +00000278: D3B2 RCALL PC+0x03B3 Relative call subroutine
    +00000279: 93800066 STS 0x0066,R24 Store direct to data space
    +0000027B: 2F82 MOV R24,R18 Copy register
    +0000027C: E06A LDI R22,0x0A Load immediate
    +0000027D: D3AD RCALL PC+0x03AE Relative call subroutine
    +0000027E: 93900067 STS 0x0067,R25 Store direct to data space
    +00000280: 912001A2 LDS R18,0x01A2 Load direct from data space
    +00000282: 2F82 MOV R24,R18 Copy register
    +00000283: E06A LDI R22,0x0A Load immediate
    +00000284: D3A6 RCALL PC+0x03A7 Relative call subroutine
    +00000285: 93800063 STS 0x0063,R24 Store direct to data space
    +00000287: 2F82 MOV R24,R18 Copy register
    +00000288: E06A LDI R22,0x0A Load immediate
    +00000289: D3A1 RCALL PC+0x03A2 Relative call subroutine
    +0000028A: 93900064 STS 0x0064,R25 Store direct to data space
    +0000028C: 91FF POP R31 Pop register from stack
    +0000028D: 91EF POP R30 Pop register from stack
    +0000028E: 91BF POP R27 Pop register from stack
    +0000028F: 91AF POP R26 Pop register from stack
    +00000290: 919F POP R25 Pop register from stack
    +00000291: 918F POP R24 Pop register from stack
    +00000292: 917F POP R23 Pop register from stack
    +00000293: 916F POP R22 Pop register from stack
    +00000294: 915F POP R21 Pop register from stack
    +00000295: 914F POP R20 Pop register from stack
    +00000296: 913F POP R19 Pop register from stack
    +00000297: 912F POP R18 Pop register from stack
    +00000298: 911F POP R17 Pop register from stack
    +00000299: 900F POP R0 Pop register from stack
    +0000029A: BE0F OUT 0x3F,R0 Out to I/O location
    +0000029B: 900F POP R0 Pop register from stack
    +0000029C: 901F POP R1 Pop register from stack
    +0000029D: 9518 RETI Interrupt return
    +0000029E: DE95 RCALL PC-0x016A Relative call subroutine
    +0000029F: 91800198 LDS R24,0x0198 Load direct from data space
    +000002A1: 3081 CPI R24,0x01 Compare with immediate
    +000002A2: F569 BRNE PC+0x2E Branch if not equal
    +000002A3: 9180019F LDS R24,0x019F Load direct from data space
    +000002A5: 2388 TST R24 Test for Zero or Minus
    +000002A6: F059 BREQ PC+0x0C Branch if equal
    +000002A7: 9210019F STS 0x019F,R1 Store direct to data space
    +000002A9: 91800060 LDS R24,0x0060 Load direct from data space
    +000002AB: 5F8F SUBI R24,0xFF Subtract immediate
    +000002AC: 93800060 STS 0x0060,R24 Store direct to data space
    +000002AE: 3188 CPI R24,0x18 Compare with immediate
    +000002AF: F014 BRLT PC+0x03 Branch if less than, signed
    +000002B0: 92100060 STS 0x0060,R1 Store direct to data space
    +000002B2: 918001A0 LDS R24,0x01A0 Load direct from data space
    +000002B4: 2388 TST R24 Test for Zero or Minus
    +000002B5: F061 BREQ PC+0x0D Branch if equal
    +000002B6: 921001A0 STS 0x01A0,R1 Store direct to data space
    +000002B8: 91800060 LDS R24,0x0060 Load direct from data space
    +000002BA: 5081 SUBI R24,0x01 Subtract immediate
    +000002BB: 93800060 STS 0x0060,R24 Store direct to data space
    +000002BD: FF87 SBRS R24,7 Skip if bit in register set
    +000002BE: C003 RJMP PC+0x0004 Relative jump
    +000002BF: E187 LDI R24,0x17 Load immediate
    +000002C0: 93800060 STS 0x0060,R24 Store direct to data space
    +000002C2: 9180011D LDS R24,0x011D Load direct from data space
    +000002C4: 2388 TST R24 Test for Zero or Minus
    +000002C5: F1E9 BREQ PC+0x3E Branch if equal
    +000002C6: E1EF LDI R30,0x1F Load immediate
    +000002C7: E0F1 LDI R31,0x01 Load immediate
    +000002C8: E09F LDI R25,0x0F Load immediate
    +000002C9: 8180 LDD R24,Z+0 Load indirect with displacement
    +000002CA: 7880 ANDI R24,0x80 Logical AND with immediate
    +000002CB: 9381 ST Z+,R24 Store indirect and postincrement
    +000002CC: 5091 SUBI R25,0x01 Subtract immediate
    +000002CD: FF97 SBRS R25,7 Skip if bit in register set
    +000002CE: CFFA RJMP PC-0x0005 Relative jump
    +000002CF: C033 RJMP PC+0x0034 Relative jump
    +000002D0: 3082 CPI R24,0x02 Compare with immediate
    +000002D1: F589 BRNE PC+0x32 Branch if not equal
    +000002D2: 9180019F LDS R24,0x019F Load direct from data space
    +000002D4: 2388 TST R24 Test for Zero or Minus
    +000002D5: F069 BREQ PC+0x0E Branch if equal
    +000002D6: 9210019F STS 0x019F,R1 Store direct to data space
    +000002D8: 9210019C STS 0x019C,R1 Store direct to data space
    +000002DA: 9180019D LDS R24,0x019D Load direct from data space
    +000002DC: 5F8F SUBI R24,0xFF Subtract immediate
    +000002DD: 9380019D STS 0x019D,R24 Store direct to data space
    +000002DF: 338C CPI R24,0x3C Compare with immediate
    +000002E0: F014 BRLT PC+0x03 Branch if less than, signed
    +000002E1: 9210019D STS 0x019D,R1 Store direct to data space
    +000002E3: 918001A0 LDS R24,0x01A0 Load direct from data space
    +000002E5: 2388 TST R24 Test for Zero or Minus
    +000002E6: F071 BREQ PC+0x0F Branch if equal
    +000002E7: 921001A0 STS 0x01A0,R1 Store direct to data space
    +000002E9: 9210019C STS 0x019C,R1 Store direct to data space
    +000002EB: 9180019D LDS R24,0x019D Load direct from data space
    +000002ED: 5081 SUBI R24,0x01 Subtract immediate
    +000002EE: 9380019D STS 0x019D,R24 Store direct to data space
    +000002F0: FF87 SBRS R24,7 Skip if bit in register set
    +000002F1: C003 RJMP PC+0x0004 Relative jump
    +000002F2: E38B LDI R24,0x3B Load immediate
    +000002F3: 9380019D STS 0x019D,R24 Store direct to data space
    +000002F5: 9180011D LDS R24,0x011D Load direct from data space
    +000002F7: 2388 TST R24 Test for Zero or Minus
    +000002F8: F051 BREQ PC+0x0B Branch if equal
    +000002F9: E1EF LDI R30,0x1F Load immediate
    +000002FA: E0F1 LDI R31,0x01 Load immediate
    +000002FB: E09F LDI R25,0x0F Load immediate
    +000002FC: 8980 LDD R24,Z+16 Load indirect with displacement
    +000002FD: 7081 ANDI R24,0x01 Logical AND with immediate
    +000002FE: 8B80 STD Z+16,R24 Store indirect with displacement
    +000002FF: 5091 SUBI R25,0x01 Subtract immediate
    +00000300: 9631 ADIW R30,0x01 Add immediate to word
    +00000301: FF97 SBRS R25,7 Skip if bit in register set
    +00000302: CFF9 RJMP PC-0x0006 Relative jump
    +00000303: 9180011C LDS R24,0x011C Load direct from data space
    +00000305: 9190011D LDS R25,0x011D Load direct from data space
    +00000307: 1789 CP R24,R25 Compare
    +00000308: F039 BREQ PC+0x08 Branch if equal
    +00000309: 9390011C STS 0x011C,R25 Store direct to data space
    +0000030B: E240 LDI R20,0x20 Load immediate
    +0000030C: E16F LDI R22,0x1F Load immediate
    +0000030D: E071 LDI R23,0x01 Load immediate
    +0000030E: E080 LDI R24,0x00 Load immediate
    +0000030F: DD66 RCALL PC-0x0299 Relative call subroutine
    +00000310: 9508 RET Subroutine return
    +00000311: DE0C RCALL PC-0x01F3 Relative call subroutine
    +00000312: 2F48 MOV R20,R24 Copy register
    +00000313: 918001A3 LDS R24,0x01A3 Load direct from data space
    +00000315: 2799 CLR R25 Clear Register
    +00000316: FD87 SBRC R24,7 Skip if bit in register cleared
    +00000317: 9590 COM R25 One's complement
    +00000318: 2F24 MOV R18,R20 Copy register
    +00000319: 2733 CLR R19 Clear Register
    +0000031A: 1728 CP R18,R24 Compare
    +0000031B: 0739 CPC R19,R25 Compare with carry
    +0000031C: F414 BRGE PC+0x03 Branch if greater or equal, signed
    +0000031D: 934001A3 STS 0x01A3,R20 Store direct to data space
    +0000031F: 9180019F LDS R24,0x019F Load direct from data space
    +00000321: 2388 TST R24 Test for Zero or Minus
    +00000322: F081 BREQ PC+0x11 Branch if equal
    +00000323: 9210019F STS 0x019F,R1 Store direct to data space
    +00000325: 918001A3 LDS R24,0x01A3 Load direct from data space
    +00000327: 5F8F SUBI R24,0xFF Subtract immediate
    +00000328: 938001A3 STS 0x01A3,R24 Store direct to data space
    +0000032A: 2799 CLR R25 Clear Register
    +0000032B: FD87 SBRC R24,7 Skip if bit in register cleared
    +0000032C: 9590 COM R25 One's complement
    +0000032D: 1728 CP R18,R24 Compare
    +0000032E: 0739 CPC R19,R25 Compare with carry
    +0000032F: F41C BRGE PC+0x04 Branch if greater or equal, signed
    +00000330: E081 LDI R24,0x01 Load immediate
    +00000331: 938001A3 STS 0x01A3,R24 Store direct to data space
    +00000333: 918001A0 LDS R24,0x01A0 Load direct from data space
    +00000335: 2388 TST R24 Test for Zero or Minus
    +00000336: F059 BREQ PC+0x0C Branch if equal
    +00000337: 921001A0 STS 0x01A0,R1 Store direct to data space
    +00000339: 918001A3 LDS R24,0x01A3 Load direct from data space
    +0000033B: 5081 SUBI R24,0x01 Subtract immediate
    +0000033C: 938001A3 STS 0x01A3,R24 Store direct to data space
    +0000033E: 1618 CP R1,R24 Compare
    +0000033F: F014 BRLT PC+0x03 Branch if less than, signed
    +00000340: 934001A3 STS 0x01A3,R20 Store direct to data space
    +00000342: 912001A3 LDS R18,0x01A3 Load direct from data space
    +00000344: 2F82 MOV R24,R18 Copy register
    +00000345: E06A LDI R22,0x0A Load immediate
    +00000346: D2E4 RCALL PC+0x02E5 Relative call subroutine
    +00000347: 93800069 STS 0x0069,R24 Store direct to data space
    +00000349: 2F82 MOV R24,R18 Copy register
    +0000034A: E06A LDI R22,0x0A Load immediate
    +0000034B: D2DF RCALL PC+0x02E0 Relative call subroutine
    +0000034C: 9390006A STS 0x006A,R25 Store direct to data space
    +0000034E: E1EF LDI R30,0x1F Load immediate
    +0000034F: E0F1 LDI R31,0x01 Load immediate
    +00000350: E097 LDI R25,0x07 Load immediate
    +00000351: 9211 ST Z+,R1 Store indirect and postincrement
    +00000352: 5091 SUBI R25,0x01 Subtract immediate
    +00000353: FF97 SBRS R25,7 Skip if bit in register set
    +00000354: CFFC RJMP PC-0x0003 Relative jump
    +00000355: E031 LDI R19,0x01 Load immediate
    +00000356: 2F83 MOV R24,R19 Copy register
    +00000357: 2799 CLR R25 Clear Register
    +00000358: 01FC MOVW R30,R24 Copy register pair
    +00000359: 59EF SUBI R30,0x9F Subtract immediate
    +0000035A: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +0000035B: 8127 LDD R18,Z+7 Load indirect with displacement
    +0000035C: 2FE2 MOV R30,R18 Copy register
    +0000035D: 27FF CLR R31 Clear Register
    +0000035E: 01DC MOVW R26,R24 Copy register pair
    +0000035F: E083 LDI R24,0x03 Load immediate
    +00000360: 0FAA LSL R26 Logical Shift Left
    +00000361: 1FBB ROL R27 Rotate Left Through Carry
    +00000362: 958A DEC R24 Decrement
    +00000363: F7E1 BRNE PC-0x03 Branch if not equal
    +00000364: 5EA1 SUBI R26,0xE1 Subtract immediate
    +00000365: 4FBE SBCI R27,0xFE Subtract immediate with carry
    +00000366: E073 LDI R23,0x03 Load immediate
    +00000367: 0FEE LSL R30 Logical Shift Left
    +00000368: 1FFF ROL R31 Rotate Left Through Carry
    +00000369: 957A DEC R23 Decrement
    +0000036A: F7E1 BRNE PC-0x03 Branch if not equal
    +0000036B: 58E4 SUBI R30,0x84 Subtract immediate
    +0000036C: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +0000036D: E097 LDI R25,0x07 Load immediate
    +0000036E: 9181 LD R24,Z+ Load indirect and postincrement
    +0000036F: 938D ST X+,R24 Store indirect and postincrement
    +00000370: 5091 SUBI R25,0x01 Subtract immediate
    +00000371: FF97 SBRS R25,7 Skip if bit in register set
    +00000372: CFFB RJMP PC-0x0004 Relative jump
    +00000373: 5F3F SUBI R19,0xFF Subtract immediate
    +00000374: 3034 CPI R19,0x04 Compare with immediate
    +00000375: F300 BRCS PC-0x1F Branch if carry set
    +00000376: 9120011D LDS R18,0x011D Load direct from data space
    +00000378: 2322 TST R18 Test for Zero or Minus
    +00000379: F039 BREQ PC+0x08 Branch if equal
    +0000037A: E2E7 LDI R30,0x27 Load immediate
    +0000037B: E0F1 LDI R31,0x01 Load immediate
    +0000037C: E09F LDI R25,0x0F Load immediate
    +0000037D: 9211 ST Z+,R1 Store indirect and postincrement
    +0000037E: 5091 SUBI R25,0x01 Subtract immediate
    +0000037F: FF97 SBRS R25,7 Skip if bit in register set
    +00000380: CFFC RJMP PC-0x0003 Relative jump
    +00000381: 9180011C LDS R24,0x011C Load direct from data space
    +00000383: 1782 CP R24,R18 Compare
    +00000384: F039 BREQ PC+0x08 Branch if equal
    +00000385: 9320011C STS 0x011C,R18 Store direct to data space
    +00000387: E240 LDI R20,0x20 Load immediate
    +00000388: E16F LDI R22,0x1F Load immediate
    +00000389: E071 LDI R23,0x01 Load immediate
    +0000038A: E080 LDI R24,0x00 Load immediate
    +0000038B: DCEA RCALL PC-0x0315 Relative call subroutine
    +0000038C: 9508 RET Subroutine return
    +0000038D: 9180019F LDS R24,0x019F Load direct from data space
    +0000038F: 2388 TST R24 Test for Zero or Minus
    +00000390: F061 BREQ PC+0x0D Branch if equal
    +00000391: 9210019F STS 0x019F,R1 Store direct to data space
    +00000393: 9180019B LDS R24,0x019B Load direct from data space
    +00000395: 5F8F SUBI R24,0xFF Subtract immediate
    +00000396: 9380019B STS 0x019B,R24 Store direct to data space
    +00000398: 308D CPI R24,0x0D Compare with immediate
    +00000399: F01C BRLT PC+0x04 Branch if less than, signed
    +0000039A: E081 LDI R24,0x01 Load immediate
    +0000039B: 9380019B STS 0x019B,R24 Store direct to data space
    +0000039D: 918001A0 LDS R24,0x01A0 Load direct from data space
    +0000039F: 2388 TST R24 Test for Zero or Minus
    +000003A0: F061 BREQ PC+0x0D Branch if equal
    +000003A1: 921001A0 STS 0x01A0,R1 Store direct to data space
    +000003A3: 9180019B LDS R24,0x019B Load direct from data space
    +000003A5: 5081 SUBI R24,0x01 Subtract immediate
    +000003A6: 9380019B STS 0x019B,R24 Store direct to data space
    +000003A8: 1618 CP R1,R24 Compare
    +000003A9: F01C BRLT PC+0x04 Branch if less than, signed
    +000003AA: E08C LDI R24,0x0C Load immediate
    +000003AB: 9380019B STS 0x019B,R24 Store direct to data space
    +000003AD: 9120019B LDS R18,0x019B Load direct from data space
    +000003AF: 2F82 MOV R24,R18 Copy register
    +000003B0: E06A LDI R22,0x0A Load immediate
    +000003B1: D279 RCALL PC+0x027A Relative call subroutine
    +000003B2: 93800066 STS 0x0066,R24 Store direct to data space
    +000003B4: 2F82 MOV R24,R18 Copy register
    +000003B5: E06A LDI R22,0x0A Load immediate
    +000003B6: D274 RCALL PC+0x0275 Relative call subroutine
    +000003B7: 93900067 STS 0x0067,R25 Store direct to data space
    +000003B9: E1EF LDI R30,0x1F Load immediate
    +000003BA: E0F1 LDI R31,0x01 Load immediate
    +000003BB: E097 LDI R25,0x07 Load immediate
    +000003BC: 9211 ST Z+,R1 Store indirect and postincrement
    +000003BD: 5091 SUBI R25,0x01 Subtract immediate
    +000003BE: FF97 SBRS R25,7 Skip if bit in register set
    +000003BF: CFFC RJMP PC-0x0003 Relative jump
    +000003C0: E031 LDI R19,0x01 Load immediate
    +000003C1: 2F83 MOV R24,R19 Copy register
    +000003C2: 2799 CLR R25 Clear Register
    +000003C3: 01FC MOVW R30,R24 Copy register pair
    +000003C4: 59EF SUBI R30,0x9F Subtract immediate
    +000003C5: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +000003C6: 8124 LDD R18,Z+4 Load indirect with displacement
    +000003C7: 2FE2 MOV R30,R18 Copy register
    +000003C8: 27FF CLR R31 Clear Register
    +000003C9: 01DC MOVW R26,R24 Copy register pair
    +000003CA: E023 LDI R18,0x03 Load immediate
    +000003CB: 0FAA LSL R26 Logical Shift Left
    +000003CC: 1FBB ROL R27 Rotate Left Through Carry
    +000003CD: 952A DEC R18 Decrement
    +000003CE: F7E1 BRNE PC-0x03 Branch if not equal
    +000003CF: 5EA1 SUBI R26,0xE1 Subtract immediate
    +000003D0: 4FBE SBCI R27,0xFE Subtract immediate with carry
    +000003D1: E093 LDI R25,0x03 Load immediate
    +000003D2: 0FEE LSL R30 Logical Shift Left
    +000003D3: 1FFF ROL R31 Rotate Left Through Carry
    +000003D4: 959A DEC R25 Decrement
    +000003D5: F7E1 BRNE PC-0x03 Branch if not equal
    +000003D6: 58E4 SUBI R30,0x84 Subtract immediate
    +000003D7: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +000003D8: E097 LDI R25,0x07 Load immediate
    +000003D9: 9181 LD R24,Z+ Load indirect and postincrement
    +000003DA: 938D ST X+,R24 Store indirect and postincrement
    +000003DB: 5091 SUBI R25,0x01 Subtract immediate
    +000003DC: FF97 SBRS R25,7 Skip if bit in register set
    +000003DD: CFFB RJMP PC-0x0004 Relative jump
    +000003DE: 5F3F SUBI R19,0xFF Subtract immediate
    +000003DF: 3034 CPI R19,0x04 Compare with immediate
    +000003E0: F300 BRCS PC-0x1F Branch if carry set
    +000003E1: 9120011D LDS R18,0x011D Load direct from data space
    +000003E3: 2322 TST R18 Test for Zero or Minus
    +000003E4: F039 BREQ PC+0x08 Branch if equal
    +000003E5: E2E7 LDI R30,0x27 Load immediate
    +000003E6: E0F1 LDI R31,0x01 Load immediate
    +000003E7: E09F LDI R25,0x0F Load immediate
    +000003E8: 9211 ST Z+,R1 Store indirect and postincrement
    +000003E9: 5091 SUBI R25,0x01 Subtract immediate
    +000003EA: FF97 SBRS R25,7 Skip if bit in register set
    +000003EB: CFFC RJMP PC-0x0003 Relative jump
    +000003EC: 9180011C LDS R24,0x011C Load direct from data space
    +000003EE: 1782 CP R24,R18 Compare
    +000003EF: F039 BREQ PC+0x08 Branch if equal
    +000003F0: 9320011C STS 0x011C,R18 Store direct to data space
    +000003F2: E240 LDI R20,0x20 Load immediate
    +000003F3: E16F LDI R22,0x1F Load immediate
    +000003F4: E071 LDI R23,0x01 Load immediate
    +000003F5: E080 LDI R24,0x00 Load immediate
    +000003F6: DC7F RCALL PC-0x0380 Relative call subroutine
    +000003F7: 9508 RET Subroutine return
    +000003F8: 9180019F LDS R24,0x019F Load direct from data space
    +000003FA: 2388 TST R24 Test for Zero or Minus
    +000003FB: F059 BREQ PC+0x0C Branch if equal
    +000003FC: 9210019F STS 0x019F,R1 Store direct to data space
    +000003FE: 918001A2 LDS R24,0x01A2 Load direct from data space
    +00000400: 5F8F SUBI R24,0xFF Subtract immediate
    +00000401: 938001A2 STS 0x01A2,R24 Store direct to data space
    +00000403: 3684 CPI R24,0x64 Compare with immediate
    +00000404: F014 BRLT PC+0x03 Branch if less than, signed
    +00000405: 921001A2 STS 0x01A2,R1 Store direct to data space
    +00000407: 918001A0 LDS R24,0x01A0 Load direct from data space
    +00000409: 2388 TST R24 Test for Zero or Minus
    +0000040A: F061 BREQ PC+0x0D Branch if equal
    +0000040B: 921001A0 STS 0x01A0,R1 Store direct to data space
    +0000040D: 918001A2 LDS R24,0x01A2 Load direct from data space
    +0000040F: 5081 SUBI R24,0x01 Subtract immediate
    +00000410: 938001A2 STS 0x01A2,R24 Store direct to data space
    +00000412: FF87 SBRS R24,7 Skip if bit in register set
    +00000413: C003 RJMP PC+0x0004 Relative jump
    +00000414: E683 LDI R24,0x63 Load immediate
    +00000415: 938001A2 STS 0x01A2,R24 Store direct to data space
    +00000417: 912001A2 LDS R18,0x01A2 Load direct from data space
    +00000419: 2F82 MOV R24,R18 Copy register
    +0000041A: E06A LDI R22,0x0A Load immediate
    +0000041B: D20F RCALL PC+0x0210 Relative call subroutine
    +0000041C: 93800063 STS 0x0063,R24 Store direct to data space
    +0000041E: 2F82 MOV R24,R18 Copy register
    +0000041F: E06A LDI R22,0x0A Load immediate
    +00000420: D20A RCALL PC+0x020B Relative call subroutine
    +00000421: 93900064 STS 0x0064,R25 Store direct to data space
    +00000423: E030 LDI R19,0x00 Load immediate
    +00000424: 2F83 MOV R24,R19 Copy register
    +00000425: 2799 CLR R25 Clear Register
    +00000426: 01FC MOVW R30,R24 Copy register pair
    +00000427: 59EF SUBI R30,0x9F Subtract immediate
    +00000428: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +00000429: 8120 LDD R18,Z+0 Load indirect with displacement
    +0000042A: 2FE2 MOV R30,R18 Copy register
    +0000042B: 27FF CLR R31 Clear Register
    +0000042C: 01DC MOVW R26,R24 Copy register pair
    +0000042D: E053 LDI R21,0x03 Load immediate
    +0000042E: 0FAA LSL R26 Logical Shift Left
    +0000042F: 1FBB ROL R27 Rotate Left Through Carry
    +00000430: 955A DEC R21 Decrement
    +00000431: F7E1 BRNE PC-0x03 Branch if not equal
    +00000432: 5EA1 SUBI R26,0xE1 Subtract immediate
    +00000433: 4FBE SBCI R27,0xFE Subtract immediate with carry
    +00000434: E043 LDI R20,0x03 Load immediate
    +00000435: 0FEE LSL R30 Logical Shift Left
    +00000436: 1FFF ROL R31 Rotate Left Through Carry
    +00000437: 954A DEC R20 Decrement
    +00000438: F7E1 BRNE PC-0x03 Branch if not equal
    +00000439: 58E4 SUBI R30,0x84 Subtract immediate
    +0000043A: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +0000043B: E097 LDI R25,0x07 Load immediate
    +0000043C: 9181 LD R24,Z+ Load indirect and postincrement
    +0000043D: 938D ST X+,R24 Store indirect and postincrement
    +0000043E: 5091 SUBI R25,0x01 Subtract immediate
    +0000043F: FF97 SBRS R25,7 Skip if bit in register set
    +00000440: CFFB RJMP PC-0x0004 Relative jump
    +00000441: 5F3F SUBI R19,0xFF Subtract immediate
    +00000442: 3034 CPI R19,0x04 Compare with immediate
    +00000443: F300 BRCS PC-0x1F Branch if carry set
    +00000444: 9120011D LDS R18,0x011D Load direct from data space
    +00000446: 2322 TST R18 Test for Zero or Minus
    +00000447: F039 BREQ PC+0x08 Branch if equal
    +00000448: E2EF LDI R30,0x2F Load immediate
    +00000449: E0F1 LDI R31,0x01 Load immediate
    +0000044A: E09F LDI R25,0x0F Load immediate
    +0000044B: 9211 ST Z+,R1 Store indirect and postincrement
    +0000044C: 5091 SUBI R25,0x01 Subtract immediate
    +0000044D: FF97 SBRS R25,7 Skip if bit in register set
    +0000044E: CFFC RJMP PC-0x0003 Relative jump
    +0000044F: 9180011C LDS R24,0x011C Load direct from data space
    +00000451: 1782 CP R24,R18 Compare
    +00000452: F039 BREQ PC+0x08 Branch if equal
    +00000453: 9320011C STS 0x011C,R18 Store direct to data space
    +00000455: E240 LDI R20,0x20 Load immediate
    +00000456: E16F LDI R22,0x1F Load immediate
    +00000457: E071 LDI R23,0x01 Load immediate
    +00000458: E080 LDI R24,0x00 Load immediate
    +00000459: DC1C RCALL PC-0x03E3 Relative call subroutine
    +0000045A: 9508 RET Subroutine return
    +0000045B: 92CF PUSH R12 Push register on stack
    +0000045C: 92DF PUSH R13 Push register on stack
    +0000045D: 92FF PUSH R15 Push register on stack
    +0000045E: 930F PUSH R16 Push register on stack
    +0000045F: 931F PUSH R17 Push register on stack
    +00000460: 93CF PUSH R28 Push register on stack
    +00000461: 93DF PUSH R29 Push register on stack
    +00000462: 91C00198 LDS R28,0x0198 Load direct from data space
    +00000464: 23CC TST R28 Test for Zero or Minus
    +00000465: F009 BREQ PC+0x02 Branch if equal
    +00000466: C0FB RJMP PC+0x00FC Relative jump
    +00000467: 91800199 LDS R24,0x0199 Load direct from data space
    +00000469: 2388 TST R24 Test for Zero or Minus
    +0000046A: F409 BRNE PC+0x02 Branch if not equal
    +0000046B: C09D RJMP PC+0x009E Relative jump
    +0000046C: 91800197 LDS R24,0x0197 Load direct from data space
    +0000046E: 2388 TST R24 Test for Zero or Minus
    +0000046F: F441 BRNE PC+0x09 Branch if not equal
    +00000470: E1EF LDI R30,0x1F Load immediate
    +00000471: E0F1 LDI R31,0x01 Load immediate
    +00000472: E747 LDI R20,0x77 Load immediate
    +00000473: 9211 ST Z+,R1 Store indirect and postincrement
    +00000474: 5041 SUBI R20,0x01 Subtract immediate
    +00000475: FF47 SBRS R20,7 Skip if bit in register set
    +00000476: CFFC RJMP PC-0x0003 Relative jump
    +00000477: DCBC RCALL PC-0x0343 Relative call subroutine
    +00000478: 91500197 LDS R21,0x0197 Load direct from data space
    +0000047A: 3056 CPI R21,0x06 Compare with immediate
    +0000047B: F009 BREQ PC+0x02 Branch if equal
    +0000047C: C057 RJMP PC+0x0058 Relative jump
    +0000047D: E040 LDI R20,0x00 Load immediate
    +0000047E: E037 LDI R19,0x07 Load immediate
    +0000047F: 2EC3 MOV R12,R19 Copy register
    +00000480: 2CD1 MOV R13,R1 Copy register
    +00000481: 2F84 MOV R24,R20 Copy register
    +00000482: 2799 CLR R25 Clear Register
    +00000483: 2F24 MOV R18,R20 Copy register
    +00000484: 9526 LSR R18 Logical shift right
    +00000485: 9526 LSR R18 Logical shift right
    +00000486: 9526 LSR R18 Logical shift right
    +00000487: 01EC MOVW R28,R24 Copy register pair
    +00000488: 1BC2 SUB R28,R18 Subtract without carry
    +00000489: 09D1 SBC R29,R1 Subtract with carry
    +0000048A: 01FC MOVW R30,R24 Copy register pair
    +0000048B: 59EF SUBI R30,0x9F Subtract immediate
    +0000048C: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +0000048D: 8180 LDD R24,Z+0 Load indirect with displacement
    +0000048E: 2FA8 MOV R26,R24 Copy register
    +0000048F: 27BB CLR R27 Clear Register
    +00000490: 2F84 MOV R24,R20 Copy register
    +00000491: 7087 ANDI R24,0x07 Logical AND with immediate
    +00000492: 2F68 MOV R22,R24 Copy register
    +00000493: 2777 CLR R23 Clear Register
    +00000494: 8181 LDD R24,Z+1 Load indirect with displacement
    +00000495: 2FE8 MOV R30,R24 Copy register
    +00000496: 27FF CLR R31 Clear Register
    +00000497: 0186 MOVW R16,R12 Copy register pair
    +00000498: 1B06 SUB R16,R22 Subtract without carry
    +00000499: 0B17 SBC R17,R23 Subtract with carry
    +0000049A: E023 LDI R18,0x03 Load immediate
    +0000049B: 0FCC LSL R28 Logical Shift Left
    +0000049C: 1FDD ROL R29 Rotate Left Through Carry
    +0000049D: 952A DEC R18 Decrement
    +0000049E: F7E1 BRNE PC-0x03 Branch if not equal
    +0000049F: 5CC1 SUBI R28,0xC1 Subtract immediate
    +000004A0: 4FDE SBCI R29,0xFE Subtract immediate with carry
    +000004A1: E093 LDI R25,0x03 Load immediate
    +000004A2: 0FEE LSL R30 Logical Shift Left
    +000004A3: 1FFF ROL R31 Rotate Left Through Carry
    +000004A4: 959A DEC R25 Decrement
    +000004A5: F7E1 BRNE PC-0x03 Branch if not equal
    +000004A6: 58E4 SUBI R30,0x84 Subtract immediate
    +000004A7: 4FFF SBCI R31,0xFF Subtract immediate with carry
    +000004A8: E083 LDI R24,0x03 Load immediate
    +000004A9: 0FAA LSL R26 Logical Shift Left
    +000004AA: 1FBB ROL R27 Rotate Left Through Carry
    +000004AB: 958A DEC R24 Decrement
    +000004AC: F7E1 BRNE PC-0x03 Branch if not equal
    +000004AD: 58A4 SUBI R26,0x84 Subtract immediate
    +000004AE: 4FBF SBCI R27,0xFF Subtract immediate with carry
    +000004AF: E017 LDI R17,0x07 Load immediate
    +000004B0: 2EF1 MOV R15,R17 Copy register
    +000004B1: 918D LD R24,X+ Load indirect and postincrement
    +000004B2: 2F28 MOV R18,R24 Copy register
    +000004B3: 2733 CLR R19 Clear Register
    +000004B4: 2E06 MOV R0,R22 Copy register
    +000004B5: C002 RJMP PC+0x0003 Relative jump
    +000004B6: 9535 ASR R19 Arithmetic shift right
    +000004B7: 9527 ROR R18 Rotate right through carry
    +000004B8: 940A DEC R0 Decrement
    +000004B9: F7E2 BRPL PC-0x03 Branch if plus
    +000004BA: 9181 LD R24,Z+ Load indirect and postincrement
    +000004BB: 2799 CLR R25 Clear Register
    +000004BC: 2E00 MOV R0,R16 Copy register
    +000004BD: C002 RJMP PC+0x0003 Relative jump
    +000004BE: 0F88 LSL R24 Logical Shift Left
    +000004BF: 1F99 ROL R25 Rotate Left Through Carry
    +000004C0: 940A DEC R0 Decrement
    +000004C1: F7E2 BRPL PC-0x03 Branch if plus
    +000004C2: 2B82 OR R24,R18 Logical OR
    +000004C3: 9389 ST Y+,R24 Store indirect and postincrement
    +000004C4: 94FA DEC R15 Decrement
    +000004C5: FEF7 SBRS R15,7 Skip if bit in register set
    +000004C6: CFEA RJMP PC-0x0015 Relative jump
    +000004C7: 5F4F SUBI R20,0xFF Subtract immediate
    +000004C8: 304B CPI R20,0x0B Compare with immediate
    +000004C9: F408 BRCC PC+0x02 Branch if carry cleared
    +000004CA: CFB6 RJMP PC-0x0049 Relative jump
    +000004CB: E8E7 LDI R30,0x87 Load immediate
    +000004CC: E0F1 LDI R31,0x01 Load immediate
    +000004CD: E047 LDI R20,0x07 Load immediate
    +000004CE: 8180 LDD R24,Z+0 Load indirect with displacement
    +000004CF: 718F ANDI R24,0x1F Logical AND with immediate
    +000004D0: 9381 ST Z+,R24 Store indirect and postincrement
    +000004D1: 5041 SUBI R20,0x01 Subtract immediate
    +000004D2: FF47 SBRS R20,7 Skip if bit in register set
    +000004D3: CFFA RJMP PC-0x0005 Relative jump
    +000004D4: 9180011C LDS R24,0x011C Load direct from data space
    +000004D6: 9190011E LDS R25,0x011E Load direct from data space
    +000004D8: 1789 CP R24,R25 Compare
    +000004D9: F409 BRNE PC+0x02 Branch if not equal
    +000004DA: C0A2 RJMP PC+0x00A3 Relative jump
    +000004DB: 9390011C STS 0x011C,R25 Store direct to data space
    +000004DD: 2F85 MOV R24,R21 Copy register
    +000004DE: 5F8F SUBI R24,0xFF Subtract immediate
    +000004DF: 93800197 STS 0x0197,R24 Store direct to data space
    +000004E1: 3784 CPI R24,0x74 Compare with immediate
    +000004E2: F038 BRCS PC+0x08 Branch if carry set
    +000004E3: 92100197 STS 0x0197,R1 Store direct to data space
    +000004E5: 92100199 STS 0x0199,R1 Store direct to data space
    +000004E7: E081 LDI R24,0x01 Load immediate
    +000004E8: 938001A1 STS 0x01A1,R24 Store direct to data space
    +000004EA: E040 LDI R20,0x00 Load immediate
    +000004EB: 2FE4 MOV R30,R20 Copy register
    +000004EC: 27FF CLR R31 Clear Register
    +000004ED: E0B3 LDI R27,0x03 Load immediate
    +000004EE: 0FEE LSL R30 Logical Shift Left
    +000004EF: 1FFF ROL R31 Rotate Left Through Carry
    +000004F0: 95BA DEC R27 Decrement
    +000004F1: F7E1 BRNE PC-0x03 Branch if not equal
    +000004F2: 5EE1 SUBI R30,0xE1 Subtract immediate
    +000004F3: 4FFE SBCI R31,0xFE Subtract immediate with carry
    +000004F4: E0A7 LDI R26,0x07 Load immediate
    +000004F5: 2EFA MOV R15,R26 Copy register
    +000004F6: 8180 LDD R24,Z+0 Load indirect with displacement
    +000004F7: 9586 LSR R24 Logical shift right
    +000004F8: 8590 LDD R25,Z+8 Load indirect with displacement
    +000004F9: 2F29 MOV R18,R25 Copy register
    +000004FA: 2733 CLR R19 Clear Register
    +000004FB: 9536 LSR R19 Logical shift right
    +000004FC: 2F32 MOV R19,R18 Copy register
    +000004FD: 2722 CLR R18 Clear Register
    +000004FE: 9537 ROR R19 Rotate right through carry
    +000004FF: 9527 ROR R18 Rotate right through carry
    +00000500: 2B82 OR R24,R18 Logical OR
    +00000501: 9381 ST Z+,R24 Store indirect and postincrement
    +00000502: 94FA DEC R15 Decrement
    +00000503: FEF7 SBRS R15,7 Skip if bit in register set
    +00000504: CFF1 RJMP PC-0x000E Relative jump
    +00000505: 5F4F SUBI R20,0xFF Subtract immediate
    +00000506: 304E CPI R20,0x0E Compare with immediate
    +00000507: F318 BRCS PC-0x1C Branch if carry set
    +00000508: C053 RJMP PC+0x0054 Relative jump
    +00000509: 918001A1 LDS R24,0x01A1 Load direct from data space
    +0000050B: 2388 TST R24 Test for Zero or Minus
    +0000050C: F181 BREQ PC+0x31 Branch if equal
    +0000050D: 91800197 LDS R24,0x0197 Load direct from data space
    +0000050F: 2388 TST R24 Test for Zero or Minus
    +00000510: F409 BRNE PC+0x02 Branch if not equal
    +00000511: DC22 RCALL PC-0x03DD Relative call subroutine
    +00000512: 9180011C LDS R24,0x011C Load direct from data space
    +00000514: 9190011E LDS R25,0x011E Load direct from data space
    +00000516: 1789 CP R24,R25 Compare
    +00000517: F409 BRNE PC+0x02 Branch if not equal
    +00000518: C064 RJMP PC+0x0065 Relative jump
    +00000519: 9390011C STS 0x011C,R25 Store direct to data space
    +0000051B: 91800197 LDS R24,0x0197 Load direct from data space
    +0000051D: 5F8F SUBI R24,0xFF Subtract immediate
    +0000051E: 93800197 STS 0x0197,R24 Store direct to data space
    +00000520: 3089 CPI R24,0x09 Compare with immediate
    +00000521: F020 BRCS PC+0x05 Branch if carry set
    +00000522: 93C00197 STS 0x0197,R28 Store direct to data space
    +00000524: 93C001A1 STS 0x01A1,R28 Store direct to data space
    +00000526: E0C0 LDI R28,0x00 Load immediate
    +00000527: E0D0 LDI R29,0x00 Load immediate
    +00000528: 018E MOVW R16,R28 Copy register pair
    +00000529: E063 LDI R22,0x03 Load immediate
    +0000052A: 2EF6 MOV R15,R22 Copy register
    +0000052B: 91200197 LDS R18,0x0197 Load direct from data space
    +0000052D: 01C8 MOVW R24,R16 Copy register pair
    +0000052E: 1B82 SUB R24,R18 Subtract without carry
    +0000052F: 0991 SBC R25,R1 Subtract with carry
    +00000530: 5D89 SUBI R24,0xD9 Subtract immediate
    +00000531: 4F9E SBCI R25,0xFE Subtract immediate with carry
    +00000532: 2F42 MOV R20,R18 Copy register
    +00000533: 01BC MOVW R22,R24 Copy register pair
    +00000534: 2F8C MOV R24,R28 Copy register
    +00000535: DB40 RCALL PC-0x04BF Relative call subroutine
    +00000536: 94FA DEC R15 Decrement
    +00000537: 5F08 SUBI R16,0xF8 Subtract immediate
    +00000538: 4F1F SBCI R17,0xFF Subtract immediate with carry
    +00000539: 9660 ADIW R28,0x10 Add immediate to word
    +0000053A: FEF7 SBRS R15,7 Skip if bit in register set
    +0000053B: CFEF RJMP PC-0x0010 Relative jump
    +0000053C: C040 RJMP PC+0x0041 Relative jump
    +0000053D: 9180011C LDS R24,0x011C Load direct from data space
    +0000053F: 91900000 LDS R25,0x0000 Load direct from data space
    +00000541: 1789 CP R24,R25 Compare
    +00000542: F1D1 BREQ PC+0x3B Branch if equal
    +00000543: 9390011C STS 0x011C,R25 Store direct to data space
    +00000545: DBEE RCALL PC-0x0411 Relative call subroutine
    +00000546: 9180011D LDS R24,0x011D Load direct from data space
    +00000548: 2388 TST R24 Test for Zero or Minus
    +00000549: F091 BREQ PC+0x13 Branch if equal
    +0000054A: E2E7 LDI R30,0x27 Load immediate
    +0000054B: E0F1 LDI R31,0x01 Load immediate
    +0000054C: E047 LDI R20,0x07 Load immediate
    +0000054D: 8180 LDD R24,Z+0 Load indirect with displacement
    +0000054E: 778F ANDI R24,0x7F Logical AND with immediate
    +0000054F: 9381 ST Z+,R24 Store indirect and postincrement
    +00000550: 5041 SUBI R20,0x01 Subtract immediate
    +00000551: FF47 SBRS R20,7 Skip if bit in register set
    +00000552: CFFA RJMP PC-0x0005 Relative jump
    +00000553: E2EF LDI R30,0x2F Load immediate
    +00000554: E0F1 LDI R31,0x01 Load immediate
    +00000555: E047 LDI R20,0x07 Load immediate
    +00000556: 8180 LDD R24,Z+0 Load indirect with displacement
    +00000557: 7F8E ANDI R24,0xFE Logical AND with immediate
    +00000558: 9381 ST Z+,R24 Store indirect and postincrement
    +00000559: 5041 SUBI R20,0x01 Subtract immediate
    +0000055A: FF47 SBRS R20,7 Skip if bit in register set
    +0000055B: CFFA RJMP PC-0x0005 Relative jump
    +0000055C: E240 LDI R20,0x20 Load immediate
    +0000055D: E16F LDI R22,0x1F Load immediate
    +0000055E: E071 LDI R23,0x01 Load immediate
    +0000055F: E080 LDI R24,0x00 Load immediate
    +00000560: DB15 RCALL PC-0x04EA Relative call subroutine
    +00000561: C01B RJMP PC+0x001C Relative jump
    +00000562: 2F8C MOV R24,R28 Copy register
    +00000563: 2799 CLR R25 Clear Register
    +00000564: 3083 CPI R24,0x03 Compare with immediate
    +00000565: 0591 CPC R25,R1 Compare with carry
    +00000566: F089 BREQ PC+0x12 Branch if equal
    +00000567: 3084 CPI R24,0x04 Compare with immediate
    +00000568: 0591 CPC R25,R1 Compare with carry
    +00000569: F434 BRGE PC+0x07 Branch if greater or equal, signed
    +0000056A: 3081 CPI R24,0x01 Compare with immediate
    +0000056B: 0591 CPC R25,R1 Compare with carry
    +0000056C: F049 BREQ PC+0x0A Branch if equal
    +0000056D: 9702 SBIW R24,0x02 Subtract immediate from word
    +0000056E: F039 BREQ PC+0x08 Branch if equal
    +0000056F: C00D RJMP PC+0x000E Relative jump
    +00000570: 3084 CPI R24,0x04 Compare with immediate
    +00000571: 0591 CPC R25,R1 Compare with carry
    +00000572: F039 BREQ PC+0x08 Branch if equal
    +00000573: 9705 SBIW R24,0x05 Subtract immediate from word
    +00000574: F039 BREQ PC+0x08 Branch if equal
    +00000575: C007 RJMP PC+0x0008 Relative jump
    +00000576: DD27 RCALL PC-0x02D8 Relative call subroutine
    +00000577: C005 RJMP PC+0x0006 Relative jump
    +00000578: DE7F RCALL PC-0x0180 Relative call subroutine
    +00000579: C003 RJMP PC+0x0004 Relative jump
    +0000057A: DE12 RCALL PC-0x01ED Relative call subroutine
    +0000057B: C001 RJMP PC+0x0002 Relative jump
    +0000057C: DD94 RCALL PC-0x026B Relative call subroutine
    +0000057D: 91DF POP R29 Pop register from stack
    +0000057E: 91CF POP R28 Pop register from stack
    +0000057F: 911F POP R17 Pop register from stack
    +00000580: 910F POP R16 Pop register from stack
    +00000581: 90FF POP R15 Pop register from stack
    +00000582: 90DF POP R13 Pop register from stack
    +00000583: 90CF POP R12 Pop register from stack
    +00000584: 9508 RET Subroutine return
    +00000585: DED5 RCALL PC-0x012A Relative call subroutine
    +00000586: 9987 SBIC 0x10,7 Skip if bit in I/O register cleared
    +00000587: C01C RJMP PC+0x001D Relative jump
    +00000588: EC84 LDI R24,0xC4 Load immediate
    +00000589: E099 LDI R25,0x09 Load immediate
    +0000058A: 9701 SBIW R24,0x01 Subtract immediate from word
    +0000058B: F7F1 BRNE PC-0x01 Branch if not equal
    +0000058C: 9987 SBIC 0x10,7 Skip if bit in I/O register cleared
    +0000058D: C016 RJMP PC+0x0017 Relative jump
    +0000058E: 9987 SBIC 0x10,7 Skip if bit in I/O register cleared
    +0000058F: C003 RJMP PC+0x0004 Relative jump
    +00000590: DECA RCALL PC-0x0135 Relative call subroutine
    +00000591: 9B87 SBIS 0x10,7 Skip if bit in I/O register set
    +00000592: CFFD RJMP PC-0x0002 Relative jump
    +00000593: 92100199 STS 0x0199,R1 Store direct to data space
    +00000595: 92100197 STS 0x0197,R1 Store direct to data space
    +00000597: 921001A1 STS 0x01A1,R1 Store direct to data space
    +00000599: 9210019A STS 0x019A,R1 Store direct to data space
    +0000059B: 91800198 LDS R24,0x0198 Load direct from data space
    +0000059D: 5F8F SUBI R24,0xFF Subtract immediate
    +0000059E: 93800198 STS 0x0198,R24 Store direct to data space
    +000005A0: 3086 CPI R24,0x06 Compare with immediate
    +000005A1: F010 BRCS PC+0x03 Branch if carry set
    +000005A2: 92100198 STS 0x0198,R1 Store direct to data space
    +000005A4: 9986 SBIC 0x10,6 Skip if bit in I/O register cleared
    +000005A5: C022 RJMP PC+0x0023 Relative jump
    +000005A6: EC84 LDI R24,0xC4 Load immediate
    +000005A7: E099 LDI R25,0x09 Load immediate
    +000005A8: 9701 SBIW R24,0x01 Subtract immediate from word
    +000005A9: F7F1 BRNE PC-0x01 Branch if not equal
    +000005AA: 9986 SBIC 0x10,6 Skip if bit in I/O register cleared
    +000005AB: C01C RJMP PC+0x001D Relative jump
    +000005AC: 9986 SBIC 0x10,6 Skip if bit in I/O register cleared
    +000005AD: C003 RJMP PC+0x0004 Relative jump
    +000005AE: DEAC RCALL PC-0x0153 Relative call subroutine
    +000005AF: 9B86 SBIS 0x10,6 Skip if bit in I/O register set
    +000005B0: CFFD RJMP PC-0x0002 Relative jump
    +000005B1: 91900198 LDS R25,0x0198 Load direct from data space
    +000005B3: 2399 TST R25 Test for Zero or Minus
    +000005B4: F031 BREQ PC+0x07 Branch if equal
    +000005B5: 9210019A STS 0x019A,R1 Store direct to data space
    +000005B7: E081 LDI R24,0x01 Load immediate
    +000005B8: 9380019F STS 0x019F,R24 Store direct to data space
    +000005BA: C00D RJMP PC+0x000E Relative jump
    +000005BB: 9180019E LDS R24,0x019E Load direct from data space
    +000005BD: 5F8F SUBI R24,0xFF Subtract immediate
    +000005BE: 9380019E STS 0x019E,R24 Store direct to data space
    +000005C0: 3180 CPI R24,0x10 Compare with immediate
    +000005C1: F014 BRLT PC+0x03 Branch if less than, signed
    +000005C2: 9390019E STS 0x019E,R25 Store direct to data space
    +000005C4: 9180019E LDS R24,0x019E Load direct from data space
    +000005C6: 6A80 ORI R24,0xA0 Logical OR with immediate
    +000005C7: DA86 RCALL PC-0x0579 Relative call subroutine
    +000005C8: 9985 SBIC 0x10,5 Skip if bit in I/O register cleared
    +000005C9: C023 RJMP PC+0x0024 Relative jump
    +000005CA: EC84 LDI R24,0xC4 Load immediate
    +000005CB: E099 LDI R25,0x09 Load immediate
    +000005CC: 9701 SBIW R24,0x01 Subtract immediate from word
    +000005CD: F7F1 BRNE PC-0x01 Branch if not equal
    +000005CE: 9985 SBIC 0x10,5 Skip if bit in I/O register cleared
    +000005CF: C01D RJMP PC+0x001E Relative jump
    +000005D0: 9985 SBIC 0x10,5 Skip if bit in I/O register cleared
    +000005D1: C003 RJMP PC+0x0004 Relative jump
    +000005D2: DE88 RCALL PC-0x0177 Relative call subroutine
    +000005D3: 9B85 SBIS 0x10,5 Skip if bit in I/O register set
    +000005D4: CFFD RJMP PC-0x0002 Relative jump
    +000005D5: 91800198 LDS R24,0x0198 Load direct from data space
    +000005D7: 2388 TST R24 Test for Zero or Minus
    +000005D8: F031 BREQ PC+0x07 Branch if equal
    +000005D9: 9210019A STS 0x019A,R1 Store direct to data space
    +000005DB: E081 LDI R24,0x01 Load immediate
    +000005DC: 938001A0 STS 0x01A0,R24 Store direct to data space
    +000005DE: 9508 RET Subroutine return
    +000005DF: 9180019E LDS R24,0x019E Load direct from data space
    +000005E1: 5081 SUBI R24,0x01 Subtract immediate
    +000005E2: 9380019E STS 0x019E,R24 Store direct to data space
    +000005E4: FF87 SBRS R24,7 Skip if bit in register set
    +000005E5: C003 RJMP PC+0x0004 Relative jump
    +000005E6: E08F LDI R24,0x0F Load immediate
    +000005E7: 9380019E STS 0x019E,R24 Store direct to data space
    +000005E9: 9180019E LDS R24,0x019E Load direct from data space
    +000005EB: 6A80 ORI R24,0xA0 Logical OR with immediate
    +000005EC: DA61 RCALL PC-0x059E Relative call subroutine
    +000005ED: 9508 RET Subroutine return
    +000005EE: E5CF LDI R28,0x5F Load immediate
    +000005EF: E0D4 LDI R29,0x04 Load immediate
    +000005F0: BFDE OUT 0x3E,R29 Out to I/O location
    +000005F1: BFCD OUT 0x3D,R28 Out to I/O location
    +000005F2: E828 LDI R18,0x88 Load immediate
    +000005F3: E133 LDI R19,0x13 Load immediate
    +000005F4: E189 LDI R24,0x19 Load immediate
    +000005F5: E090 LDI R25,0x00 Load immediate
    +000005F6: 9701 SBIW R24,0x01 Subtract immediate from word
    +000005F7: F7F1 BRNE PC-0x01 Branch if not equal
    +000005F8: 5021 SUBI R18,0x01 Subtract immediate
    +000005F9: 4030 SBCI R19,0x00 Subtract immediate with carry
    +000005FA: F7C9 BRNE PC-0x06 Branch if not equal
    +000005FB: DB15 RCALL PC-0x04EA Relative call subroutine
    +000005FC: DBD1 RCALL PC-0x042E Relative call subroutine
    +000005FD: DAB1 RCALL PC-0x054E Relative call subroutine
    +000005FE: 91800069 LDS R24,0x0069 Load direct from data space
    +00000600: E09A LDI R25,0x0A Load immediate
    +00000601: 9F89 MUL R24,R25 Multiply unsigned
    +00000602: 0190 MOVW R18,R0 Copy register pair
    +00000603: 2411 CLR R1 Clear Register
    +00000604: 9180006A LDS R24,0x006A Load direct from data space
    +00000606: 0F82 ADD R24,R18 Add without carry
    +00000607: 938001A3 STS 0x01A3,R24 Store direct to data space
    +00000609: 91800066 LDS R24,0x0066 Load direct from data space
    +0000060B: 9F89 MUL R24,R25 Multiply unsigned
    +0000060C: 0190 MOVW R18,R0 Copy register pair
    +0000060D: 2411 CLR R1 Clear Register
    +0000060E: 91800067 LDS R24,0x0067 Load direct from data space
    +00000610: 0F82 ADD R24,R18 Add without carry
    +00000611: 9380019B STS 0x019B,R24 Store direct to data space
    +00000613: 91800063 LDS R24,0x0063 Load direct from data space
    +00000615: 9F89 MUL R24,R25 Multiply unsigned
    +00000616: 0190 MOVW R18,R0 Copy register pair
    +00000617: 2411 CLR R1 Clear Register
    +00000618: 91800064 LDS R24,0x0064 Load direct from data space
    +0000061A: 0F82 ADD R24,R18 Add without carry
    +0000061B: 938001A2 STS 0x01A2,R24 Store direct to data space
    +0000061D: E78F LDI R24,0x7F Load immediate
    +0000061E: DADE RCALL PC-0x0521 Relative call subroutine
    +0000061F: E888 LDI R24,0x88 Load immediate
    +00000620: E193 LDI R25,0x13 Load immediate
    +00000621: 9701 SBIW R24,0x01 Subtract immediate from word
    +00000622: F7F1 BRNE PC-0x01 Branch if not equal
    +00000623: DB10 RCALL PC-0x04EF Relative call subroutine
    +00000624: E240 LDI R20,0x20 Load immediate
    +00000625: E16F LDI R22,0x1F Load immediate
    +00000626: E071 LDI R23,0x01 Load immediate
    +00000627: E080 LDI R24,0x00 Load immediate
    +00000628: DA4D RCALL PC-0x05B2 Relative call subroutine
    +00000629: DF5B RCALL PC-0x00A4 Relative call subroutine
    +0000062A: CFFE RJMP PC-0x0001 Relative jump
    +0000062B: FB87 BST R24,7 Bit store from register to T
    +0000062C: 2E08 MOV R0,R24 Copy register
    +0000062D: 2606 EOR R0,R22 Exclusive OR
    +0000062E: FD87 SBRC R24,7 Skip if bit in register cleared
    +0000062F: 9581 NEG R24 Two's complement
    +00000630: FD67 SBRC R22,7 Skip if bit in register cleared
    +00000631: 9561 NEG R22 Two's complement
    +00000632: D005 RCALL PC+0x0006 Relative call subroutine
    +00000633: F40E BRTC PC+0x02 Branch if T flag cleared
    +00000634: 9591 NEG R25 Two's complement
    +00000635: FC07 SBRC R0,7 Skip if bit in register cleared
    +00000636: 9581 NEG R24 Two's complement
    +00000637: 9508 RET Subroutine return
    +00000638: 1B99 SUB R25,R25 Subtract without carry
    +00000639: E079 LDI R23,0x09 Load immediate
    +0000063A: C004 RJMP PC+0x0005 Relative jump
    +0000063B: 1F99 ROL R25 Rotate Left Through Carry
    +0000063C: 1796 CP R25,R22 Compare
    +0000063D: F008 BRCS PC+0x02 Branch if carry set
    +0000063E: 1B96 SUB R25,R22 Subtract without carry
    +0000063F: 1F88 ROL R24 Rotate Left Through Carry
    +00000640: 957A DEC R23 Decrement
    +00000641: F7C9 BRNE PC-0x06 Branch if not equal
    +00000642: 9580 COM R24 One's complement
    +00000643: 9508 RET Subroutine return
    +00000644: 020C MULS R16,R28 Multiply signed
    +00000645: 0100 MOVW R0,R0 Copy register pair
    +00000646: 1000 CPSE R0,R0 Compare, skip if equal
    +00000647: 0400 CPC R0,R0 Compare with carry
    +00000648: 0111 MOVW R2,R2 Copy register pair
    +00000649: 1201 CPSE R0,R17 Compare, skip if equal
    +0000064A: 0000 NOP No operation
    +0000064B: 0101 MOVW R0,R2 Copy register pair
    +0000064C: 0302 MULSU R16,R18 Multiply signed with unsigned
    +0000064D: 0403 CPC R0,R3 Compare with carry
    +0000064E: 0505 CPC R16,R5 Compare with carry
    +0000064F: 0606 CPC R0,R22 Compare with carry
    +00000650: 0807 SBC R0,R7 Subtract with carry
    +00000651: 0908 SBC R16,R8 Subtract with carry
    +00000652: 423C SBCI R19,0x2C Subtract immediate with carry
    +00000653: 4A46 SBCI R20,0xA6 Subtract immediate with carry
    +00000654: 6252 ORI R21,0x22 Logical OR with immediate
    +00000655: 3C42 CPI R20,0xC2 Compare with immediate
    +00000656: 1810 SUB R1,R0 Subtract without carry
    +00000657: 1014 CPSE R1,R4 Compare, skip if equal
    +00000658: 1010 CPSE R1,R0 Compare, skip if equal
    +00000659: 7E10 ANDI R17,0xE0 Logical AND with immediate
    +0000065A: 423C SBCI R19,0x2C Subtract immediate with carry
    +0000065B: 2040 AND R4,R0 Logical AND
    +0000065C: 0810 SBC R1,R0 Subtract with carry
    +0000065D: 7E04 ANDI R16,0xE4 Logical AND with immediate
    +0000065E: 423C SBCI R19,0x2C Subtract immediate with carry
    +0000065F: 3C40 CPI R20,0xC0 Compare with immediate
    +00000660: 4040 SBCI R20,0x00 Subtract immediate with carry
    +00000661: 3C42 CPI R20,0xC2 Compare with immediate
    +00000662: 3020 CPI R18,0x00 Compare with immediate
    +00000663: 2428 EOR R2,R8 Exclusive OR
    +00000664: 7E22 ANDI R18,0xE2 Logical AND with immediate
    +00000665: 2020 AND R2,R0 Logical AND
    +00000666: 027E MULS R23,R30 Multiply signed
    +00000667: 3E02 CPI R16,0xE2 Compare with immediate
    +00000668: 4040 SBCI R20,0x00 Subtract immediate with carry
    +00000669: 3C42 CPI R20,0xC2 Compare with immediate
    +0000066A: 023C MULS R19,R28 Multiply signed
    +0000066B: 3E02 CPI R16,0xE2 Compare with immediate
    +0000066C: 4242 SBCI R20,0x22 Subtract immediate with carry
    +0000066D: 3C42 CPI R20,0xC2 Compare with immediate
    +0000066E: 407E SBCI R23,0x0E Subtract immediate with carry
    +0000066F: 1020 CPSE R2,R0 Compare, skip if equal
    +00000670: 0408 CPC R0,R8 Compare with carry
    +00000671: 0404 CPC R0,R4 Compare with carry
    +00000672: 423C SBCI R19,0x2C Subtract immediate with carry
    +00000673: 3C42 CPI R20,0xC2 Compare with immediate
    +00000674: 4242 SBCI R20,0x22 Subtract immediate with carry
    +00000675: 3C42 CPI R20,0xC2 Compare with immediate
    +00000676: 423C SBCI R19,0x2C Subtract immediate with carry
    +00000677: 4242 SBCI R20,0x22 Subtract immediate with carry
    +00000678: 407C SBCI R23,0x0C Subtract immediate with carry
    +00000679: 3C42 CPI R20,0xC2 Compare with immediate
    +0000067A: 423C SBCI R19,0x2C Subtract immediate with carry
    +0000067B: 4242 SBCI R20,0x22 Subtract immediate with carry
    +0000067C: 427E SBCI R23,0x2E Subtract immediate with carry
    +0000067D: 4242 SBCI R20,0x22 Subtract immediate with carry
    +0000067E: 423E SBCI R19,0x2E Subtract immediate with carry
    +0000067F: 3E42 CPI R20,0xE2 Compare with immediate
    +00000680: 4242 SBCI R20,0x22 Subtract immediate with carry
    +00000681: 3E42 CPI R20,0xE2 Compare with immediate
    +00000682: 423C SBCI R19,0x2C Subtract immediate with carry
    +00000683: 0202 MULS R16,R18 Multiply signed
    +00000684: 0202 MULS R16,R18 Multiply signed
    +00000685: 3C42 CPI R20,0xC2 Compare with immediate
    +00000686: 221E AND R1,R30 Logical AND
    +00000687: 4242 SBCI R20,0x22 Subtract immediate with carry
    +00000688: 4242 SBCI R20,0x22 Subtract immediate with carry
    +00000689: 1E22 ADC R2,R18 Add with carry
    +0000068A: 027E MULS R23,R30 Multiply signed
    +0000068B: 7E02 ANDI R16,0xE2 Logical AND with immediate
    +0000068C: 0202 MULS R16,R18 Multiply signed
    +0000068D: 7E02 ANDI R16,0xE2 Logical AND with immediate
    +0000068E: 027E MULS R23,R30 Multiply signed
    +0000068F: 3E02 CPI R16,0xE2 Compare with immediate
    +00000690: 0202 MULS R16,R18 Multiply signed
    +00000691: 0202 MULS R16,R18 Multiply signed
    +00000692: 7C04 ANDI R16,0xC4 Logical AND with immediate
    +00000693: 3C12 CPI R17,0xC2 Compare with immediate
    +00000694: 7E14 ANDI R17,0xE4 Logical AND with immediate
    +00000695: 1010 CPSE R1,R0 Compare, skip if equal
    +00000696: 447C SBCI R23,0x4C Subtract immediate with carry
    +00000697: 447C SBCI R23,0x4C Subtract immediate with carry
    +00000698: 447C SBCI R23,0x4C Subtract immediate with carry
    +00000699: 4264 SBCI R22,0x24 Subtract immediate with carry
    +0000069A: 427E SBCI R23,0x2E Subtract immediate with carry
    +0000069B: 7E42 ANDI R20,0xE2 Logical AND with immediate
    +0000069C: 4242 SBCI R20,0x22 Subtract immediate with carry
    +0000069D: 427E SBCI R23,0x2E Subtract immediate with carry
    +0000069E: 443A SBCI R19,0x4A Subtract immediate with carry
    +0000069F: 0404 CPC R0,R4 Compare with carry
    +000006A0: 0404 CPC R0,R4 Compare with carry
    +000006A1: 3844 CPI R20,0x84 Compare with immediate
    +000006A2: FFFF ??? Data or unknown opcode

    Add A Comment: